TDK-Lambda
PFE300SA
C274-01-01A
SPECIFICATIONS
MODEL
ITEMS
1 Nominal Output Voltage
V
12
28
48
2 Maximum Output Current
A
25
10.8
6.3
3 Nominal Output Power
W
300
302.4
302.4
4 Efficiency (Typ.)
(*1)
%
84 / 85
87/ 89
88 / 90
5 Input Voltage Range
(*2)(*5)(*9)
-
85 - 265 VAC
6 Input Frequency
(*2)
Hz
47 - 63
7 Input Current
(*1)
A
3.8 / 1.9
3.7 / 1.8
3.6 / 1.8
8 Power Factor
(*1)(*5)
-
0.95 min
9 Output Voltage Accuracy
(*1)
%
+/-2
10 Output Voltage Range
%
-20 / +20
11 Maximum Ripple & Noise
(*5)
mV
120
280
480
12 Maximum Line Regulation
mV
48
56
96
13 Maximum Load Regulation
mV
48
56
96
14 Over Current Protection
-
105% - 140% (Automatic recovery method)
15 Over Voltage Protection
-
125% - 145% (Inverter shutdown method)
16 In-rush Current (Typ.)
(*1)(*5)(*6)
A
20A / 40A peak
17 Parallel Operation
-
-
18 Series Operation
(*7)
-
Possible
19 Operating Temperature
(*3)(*8)
-
20 Operating Humidity
-
20 - 95%RH (No Dewdrop)
21 Storage Temperature
-
-40°C - +100°C
22 Storage Humidity
-
10 - 95%RH (No Dewdrop)
23 Cooling
(*4)
-
Conduction Cooled
24 Temperature Coefficient
-
Less than 0.02% / °C
25 Withstand Voltage
-
Input-Baseplate : 2.5kVAC, Input-Output : 3.0kVAC for 1min.
Output-Baseplate : 1.5kVDC for 1min.
26 Isolation Resistance
-
Output to Baseplate 500VDC more than 100M
W
(25°C,70%RH)
27 Vibration
-
At No Operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm Constant (Maximum 49.0m/s
2
) X,Y,Z 1 hour each
28 Shock
-
196.1m/s
2
29 Safety
-
Approved by UL60950-1,CSA60950-1,EN60950-1
30 Weight (Typ.)
g
200
31 Size (W x H x D)
mm
61 x 12.7 x 116.8 (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
Derating Curve
=NOTES=
*1. At 100VAC/200VAC and maximum output power.
(Baseplate Temperature = +25°C.)
*2. For cases where conformance to various safety specs
(UL, CSA, EN) are required, input voltage range
will be 100 - 240VAC(50 - 60Hz).
*3. Ratings - refer to Derating Curve on the right.
*4. Heatsink has to be chosen according to Instruction manual.
*5. External components are needed for operation.
(Refer to basic connection and instruction manual.)
*6. First inrush current. Not applicable for the inrush current to
Noise Filter for less than 0.2ms.
*7. Refer to Instruction manual.
*8. Ambient Temperature min=-40°C.
*9. Start-up at Vin=83VAC guaranteed.
PFE300SA-12
PFE300SA-28
PFE300SA-48
-40°C - +100°C
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
L
oa
d
(
%
)
Baseplate Temperature (
℃
)