TDK-Lambda HWS300P Series Скачать руководство пользователя страница 1

 

A237-04-01C

 

- 1- 

TDK-Lambda 

HWS300P-600P Series 
INSTRUCTION MANUAL

 

 

  

HWS300P-600P Series 

Instruction Manual 

BEFORE USING THE POWER SUPPLY UNIT 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before 
using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. 

 DANGER

 

Never use this product in locations where flammable gas or ignitable substances are present. 

 INSTALLATION WARNING 

·

 

When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is risk of 
electric shock and fire. 

·

 

Installation shall be done by Service personnel with necessary and appropriate technical training and experience. There is a risk of 
electric shock and fire. 

·

 

Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage, electric shock 
or fire. 

 WARNING on USE 

·

 

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a burn. 

·

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

·

 

There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in operation as 
you might get injured due to high voltage and high temperature. You might also get electric shock or burn. 

·

 

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage the 
product. We will not be held responsible after the product has been modified, changed or dis-assembled. 

·

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop using it 
immediately and shut off the product. 
It might lead to fire and electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the 
user. 

·

 

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might lead fire 
and electric shock. 

·

 

Do not drop or apply shock to this product. It might cause failure. Do not operate these products mechanical stress is applied. 

 CAUTION on MOUNTING

 

·

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. 

·

 

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, 
otherwise the product will be damaged.  

·

 

Input line, please use the wires as short and thick as possible. 

·

 

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and direct 
sunlight, or places where product is exposed to water or rain. 

·

 

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be ventilated. 

·

 

Please shut down the input when connecting input and output of the product. 

·

 

When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration of above 
foreign material in the power supply by installing filter, to prevent trouble or malfunction.  

 CAUTION on USE

 

·

 

Product individual notes are shown in the instruction manual. If there is any difference with common notes individual notes shall 
have priority. 

·

 

Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the 
product or fire due to improper use. 

·

 

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, 
otherwise the product will be damaged, or cause electric shock or fire. 

·

 

If the built-in fuse is blown, do not use the product even after replacing the fuse, as there is risk of abnormality inside. Be sure to 
request repair to our company. 

Содержание HWS300P Series

Страница 1: ...o fire and electric shock In such cases please contact us Do not attempt repair by yourself as it is dangerous for the user Do not operate and store these products in environments where condensation o...

Страница 2: ...ke care not to apply external abnormal voltage to the output Especially applying reverse voltage or overvoltage more than the rated voltage to the output might cause failure electric shock or fire Thi...

Страница 3: ...by applying voltage to the aluminum electrolytic capacitor to reduce the increased leakage current through the self recovery effect of the electrolyte For reference before using products that have be...

Страница 4: ...mmer The output voltage rises when a trimmer is turned clockwise ON Output Power On indication LED The indicator turns on when the power supply output is in normal operating condition CN1 Remote ON OF...

Страница 5: ...l signal 6 TOG GND for CNT and PF signals Same as Pin No 8 7 PF Power fail signal PF signal output terminal Uses the open collector method As the output voltage drops or Fan stops Power Fail terminal...

Страница 6: ...mbda HWS300P 600P Series INSTRUCTION MANUAL 3 Block Diagram HWS300P HWS600P Line Filter Rectifier PFHC Circuit Inrush Current Limit Circuit Filter Switching Circuit Control Circuit Control Circuit Rec...

Страница 7: ...Point 65 80 of Nominal Voltage Input Voltage Output Voltage Remote ON OFF Control 1 Power Fail PF Signal Open collector Input on Input off Input on Input off Remote off Remote on OVP act on Delay shu...

Страница 8: ...l or chassis Remote ON OFF control lines shall be twisted or used shielded wires Separate from load line Output current of each terminal screw shall be less than 40A for HWS300P And shall be less than...

Страница 9: ...at the time of the consecutive peak current When the product operate peak current for more than 5 seconds delay shut down function operates and the output will be shut down To reset delay shut down re...

Страница 10: ...stor can be used as ON OFF switch 3 Remote ON OFF control circuit is isolated from the input and output by a photo coupler and can be controlled regardless of the output potential or Connect TOG termi...

Страница 11: ...terminals COM terminals shall be as short as possible and same length and twisted Parallel operation is possible up to 2 units 1 Adjust the output voltage of each power supply to be same value within...

Страница 12: ...tween output and Frame ground and 100VAC between output and CNT PF terminal each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 20mA Output Frame...

Страница 13: ...erates and the output will shut down Peak output power and average output power use less than specification Peak output power is limited depending on Duty The details see at b The product might be dam...

Страница 14: ...ak output power W Duty 20 35 30 25 40 7 Mounting Directions 7 1 Output Derating according to the Mounting Directions Recommended standard mounting method is A Method B is also possible Refer to the de...

Страница 15: ...Wire size to use for SPHD 001T P0 5 is AWG 26 AWG 22 and insulation outer diameter is 1 0 1 5 mm Wire size to use for SPHD 002T P0 5 is AWG 28 AWG 24 and insulation outer diameter is 0 9 1 5 mm Crimpi...

Страница 16: ...o crimped part and insert contact parallel to housing 2 Insert contact into housing without stopping to innermost 3 Check secure locking per each insertion by pulling wire softly in order to check tha...

Страница 17: ...that the unit is at fault make the following checks 1 Check if the rated input voltage is connected 2 Check if the wiring of input and output is correct 3 Check if the I O terminal connection is prop...

Отзывы: