BEFORE USING THE POWER SUPPLY UNIT

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings 
before using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

DANGER

Never use this product in locations where flammable gas or ignitable substances are present.

INSTALLATION WARNING

•  When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, 

there is risk of electric shock and fire. 

•  Installation shall be done by Service personnel with necessary and appropriate technical training and experience.

There is a risk of electric shock and fire. 

•  Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage, 

electric shock or fire.

WARNING ON USE

•  Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may 

receive a burn.

•  While this product is operating, keep your hands and face away from it as you may be injured by an unexpected 

situation. 

•  There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in 

operation as you might get injured due to high voltage and high temperature. You might also get electric shock or 

burn. 

•  Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might 

damage the product. We will not be held responsible after the product has been modified, changed or dis-assembled. 

•  Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please 

stop using it immediately and shut off the product.

It might lead to fire and electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is 
dangerous for the user.

•  Do not operate and store these products in environments where condensation occurs due to moisture and humidity. 

It might lead fire and electric shock.

•  Do not drop or apply shock to this product. It might cause  failure. Do not operate these products mechanical stress is 

applied.

CAUTION ON MOUNTING

•  Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on.
•  Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within 

specifications, otherwise the product will be damaged. 

•  Input line, please use the wires as short and thick as possible.
•  Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive 

substances and direct sunlight, or places where product is exposed to water  or rain.

•  Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be 

ventilated.

•  Please shut down the input when connecting input and output of the product.
•  When installing  in environment where conductive foreign, dust and liquid may be present, 

please consider penetration of above foreign material in the power supply by installing filter, to prevent trouble or
malfunction.

HWS300

600 Series 

Instruction Manual

 

Содержание HWS300 Series

Страница 1: ...might damage the product We will not be held responsible after the product has been modified changed or dis assembled Do not use this product under unusual condition such as emission of smoke or abnor...

Страница 2: ...malfunction When used in environment with corrosive gas hydrogen sulfide sulfur dioxide etc there is possibility that they might penetrate the product and lead to failure When used in environments whe...

Страница 3: ...m storage period we recommend to use within 2 years after receiving the product There is tendency that the leakage current of an aluminium electrolytic capacitor may increase when stored without using...

Страница 4: ...on HWS300 HWS600 V ADJ Output voltage adjustment trimmer The output voltage rises when a trimmer is turned clockwise ON Output Power On indication LED The indicator turns on when the power supply outp...

Страница 5: ...h compensates for line drop between power supply terminals and load terminals Connect to Vm terminal when remote sensing function unnecessary 5 PC Current balance terminal For output current balancing...

Страница 6: ...control lines shall be twisted or used shielded wires Separate from load line Output current of each terminal screw shall be less than 40A for HWS300 And shall be less than 60A for HWS600 HWS300 Panel...

Страница 7: ...output terminal which may leads damage In the case of inductive load use decoupling diode at output line 4 4 Over Current Protection OCP The OCP function is provided OCP characteristic is constant cu...

Страница 8: ...mote ON OFF Control Remote ON OFF control is provided Using this function output on off is allowed to control without input voltage on off The output is turned to ON when TOG and CNT terminals are sho...

Страница 9: ...etc might be necessary to use across the load terminal The output ripple cannot be measure accurately if the probe ground lead of oscilloscope is too long 4 10 Series Operation For series operation bo...

Страница 10: ...to a single point on the load Please refer connection Method A 2 1 Adjust the output voltage of each power supply to be same value within 1 or 100mV whichever is smaller 2 Use same length and type of...

Страница 11: ...0VAC between output and chassis and 100VAC between output and CNT PF terminal each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 20mA Output chas...

Страница 12: ...V to PV terminal and COM terminal Note if an external voltage is not applied there will be no output Please consider the following characteristics Note 1 Regarding output voltage adjustment below 20 p...

Страница 13: ...utput current Average DC output current Im Within the rated output current Ip Peak output current A Iav Rated output current A Im Average output current A Peak current pulse width sec T Period sec 5 M...

Страница 14: ...siderations connect terminal to the mounting set ground terminal 6 Recommended torque for the terminal HWS600 Output terminal M5 screw 2 50 N m 25 5kgf cm HWS300 Input Output terminal HWS600 Input ter...

Страница 15: ...4 1 5 0 62 0 67 1 8 Note 1 Crimp height at wire barrel should be set to pre determined dimensions Note 2 Adjust crimp height at wire insulation barrel to the extent that wire insulation is slightly pr...

Страница 16: ...g of wire 7 The life expectancy The life of the power supply depends on the life of the built in aluminum electrolytic capacitor being used and fan mounted products will depend on fan life Each life i...

Страница 17: ...is not opened If in open condition power supply will not output 7 Check if the built in FAN is not stopped Is FAN stopped by something irregulars or etc If FAN stops the PF signal turn High level and...

Отзывы: