TDK-Lambda HWS 1500/ME Series Скачать руководство пользователя страница 1

 

-1- 

TDK-Lambda 

HWS1500/ME Series

 

INSTRUCTION MANUAL

   

 

 

   

HWS 1500/ME Series

   

Instruction Manual

 

DA006-04-80/ME-E 

BEFORE USING THE POWER SUPPLY UNIT

 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using 
this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. 
 

  DANGER 

·

 

Never use this product in locations where flammable gas or ignitable substances are present. 

 

  INSTALLATION WARNING

 

·

 

When installing, ensure that work is done in accordance with the instruction manual. 
When installation is improper, there is risk of electric shock and fire. 

·

 

Installation shall be done by Service personnel with necessary and appropriate technical training and experience. 
There is a risk of electric shock and fire. 

·

 

Do not cover the product with cloth or paper etc. Do not place anything flammable around. 
This might cause damage, electric shock or fire. 

 

  WARNING on USE

 

·

 

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a burn. 

·

 

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation. 

·

 

For products with no cover, do not touch them as there are high-voltage and high temperature parts inside. 
Touching them might cause injury such as electric shock or burn. 

·

 

There are cases where high voltage charge remains inside the product immediately after the input is cut off. 
Therefore, do not touch even if they are not in operation as you might get injured due to high voltage and high temperature. 
You might also get electric shock or burn. 

·

 

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage the 
product. We will not be held responsible after the product has been modified, changed or dis-assembled. 

·

 

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. 
Please stop using it immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. 
Do not attempt repair by yourself, as it is dangerous for the user. 

·

 

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. 
It might lead fire and electric shock. 

·

 

Do not drop or apply shock to this product. It might cause failure. Do not operate these products mechanical stress is applied. 

·

 

When necessary, this products is to be repaired only by us or our authorized agents. It is important that this product cannot be used 
in hazardous environments (facilities such as nuclear power control system or life support equipment) without our written consent. 

·

 

Do not drop or insert anything into unit. It might cause failure and fire, when using the unit under such condition. 

·

 

The outputs of these products must be earthed in the end use equipment to maintain SELV.   
If the outputs are not earthed, they must be considered hazardous and must not be made user accessible. 

 

  CAUTION on MOUNTING

 

·

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on. 

·

 

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, 
otherwise the product will be damaged. 

·

 

Input line, please use the wires as short and thick as possible. 

·

 

Do not use this product in special environment with strong electromagnetic field, corrosive gas or conductive substances and 
direct sunlight, or places where product is exposed to water or rain. 

·

 

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly ventilated. 

·

 

Please shut down the input when connecting input and output of the product. 

·

 

When installing in environment where conductive foreign, dust and liquid may be present, please consider penetration of above 
foreign material in the power supply by installing filter, to prevent trouble or malfunction. 

·

 

This power supply is primarily designed and manufactured to use and enclose in other equipment. 

·

 

This power supply unit has a built-in fan for air-cooling. Do not block air intake and exhaust. It might cause fire. 

·

 

Do not operate and store this unit at the condition of condensation. In such case, waterproof treatment is necessary. 

Содержание HWS 1500/ME Series

Страница 1: ...o fire and electric shock In such cases please contact us Do not attempt repair by yourself as it is dangerous for the user Do not operate and store these products in environments where condensation o...

Страница 2: ...design such as providing protective circuit or protective device inside the system providing redundant circuit to ensure no instability when single device failure occurs When used in environments with...

Страница 3: ...that traces of sheet metal processing be left in our power supplies When disposing product follow disposal laws of each municipality Published EMI CE RE or immunity is the result when measured in our...

Страница 4: ...t chassis Remote sensing lines shall be twisted or use the shielded wire Remote ON OFF control lines shall be twisted or use the shielded wire 2 1 Front Panel Explanation HWS1500 Front Panel Output te...

Страница 5: ...e sensing function is unnecessary 5 PC Current balance terminal For output current balancing in parallel operation 6 COM Ground for PC and PV signal 7 PV Output voltage external control terminal For p...

Страница 6: ...ltage will deteriorate when the sensing terminals are opened In the following cases the output is shut down When CNT and TOG is opened When PV and REF is opened Attached connector when shipping Connec...

Страница 7: ...onnecting to the load line These are not attached to the product Load Connector JST S12B PHDSS Remove standard attached connector and use the harness made by the customer Housing JST PHDR 12VS Contact...

Страница 8: ...er Rectifier Filter Input 85 265VAC E Output CNT TOG Remote ON OFF Control S S COM PV Output Current Balance PC PF Standby supply Latch Circuit OVP Circuit UVP Circuit Low output Voltage Detection Pho...

Страница 9: ...TION OTP ACTION REMOTE OFF REMOTE OFF REMOTE OFF REMOTE OFF REMOTE ON REMOTE ON REMOTE ON REMOTE ON FAN STOP FAN ALM ACTION SHUT DOWN 5sec TYP 5sec TYP OCP Point 105 or more 3 OCP Shut down 1 Level 2...

Страница 10: ...current limiting Time delay shutdown type is provided OCP function operates when the output current exceeds 105 of maximum DC output current specification and the over current or short circuit conditi...

Страница 11: ...is connected The output is turned to ON when TOG and CNT terminals are shorted and output is turned to OFF when these terminals are opened When the function is not used connect TOG and CNT terminals...

Страница 12: ...cope is too long 5 10 Series Operation For series operation either method A or B is possible There might be a step in the rise waveform during series operation Note1 Please connect a diode for by pass...

Страница 13: ...balancing function is the static power up Therefore the output voltage might decrease according to the condition of dynamic load There might be a step in the rise waveform during parallel operation 4...

Страница 14: ...tween output and CNT PF shall be more than 10MW at 100VDC For safety operation voltage setting of DC isolation tester must be done before the test Ensure that it is fully discharged after the test CNT...

Страница 15: ...may be damaged by high impulse voltage at timer switch on and off Connect input and output as follows If output is left open during test output voltage might appear momentarily This product have mono...

Страница 16: ...er Supply Load 1 6V DC COM Output Voltage Linearity PV Voltage Nominal Input Voltage 20 Nominal Output Voltage Output V 5V 1V 5 5V 6V 0 120 110 Note Only as for the type of 48V output the output volta...

Страница 17: ...re 1 PV terminal and REF terminal is short by using standard connector supplied 2 Set the power supply output voltage to maximum value of the output voltage variable range mentioned in specification s...

Страница 18: ...ion circuit is activated input is temporarily cut off for a few minutes and then power is re input or remote ON OFF control signal should be input for recovery of the output Input voltage range AC180V...

Страница 19: ...and more than 50mm from rear side 3 Please note that ventilation will be worsened in a dusty environment 4 Built in fan is limited life part which require periodic replacement Replacement will be cha...

Страница 20: ...prove noise sensitivity 4 Attaching a capacitor to the load terminals can eliminate noise 5 E terminal of this power supply is functional earthing For safety purposes connect protective earthing termi...

Страница 21: ...s properly adjusted OVP might be triggered and output is cut off 6 Check if the wiring of S and S terminal is correct If in open condition the stability and the accuracy of the output deteriorate 7 If...

Страница 22: ...aintenance or exchange the product which passed over the life expectancy 11 Warranty Period This product is warranted for a period of 5 years from the date of shipment For damages occurring at normal...