TDK-Lambda HFE1600/S series Скачать руководство пользователя страница 1

IA688-04-01/S Rev. G 

HFE1600/S (PMBUS) SERIES INSTRUCTION MANUAL 

CHAPTER 1:

 

HFE1600/S (PMBus) SERIES SPECIFICATIONS .......................................................1

 

1.1  HFE1600 rated output Current and Voltage versus Line Voltage. ............................. 3 
1.2  HFE1600 Output Power vs. Temp derating. ............................................................... 4 
1.3  HFE1600 Outline Drawing .......................................................................................... 5 
1.4  Rear Panel IN/OUT Connector Pins Function Description ..................................... 6 

CHAPTER 2:

 

SAFETY APPROVALS ...........................................................................................7

 

2.1  Safety Instructions ...................................................................................................... 7 

CHAPTER 3:

 

SINGLE UNIT OPERATION ................................................................................. 10

 

3.1  Front Panel Indicators .............................................................................................. 10 
3.2  Single unit operation ................................................................................................ 11 

3.2.1  Basic configuration (Local Sense) ............................................................... 11 

3.2.2  Basic configuration (Remote Sense) ........................................................... 11 

3.2.3  ON/OFF Control by Enable .......................................................................... 12 

3.2.4  ON/OFF Control by INHIBIT ........................................................................ 12 

3.2.5  Output Voltage Programming by External Voltage .................................... 12 

3.2.6  Output Voltage Programming by PMBus ................................................... 13 

3.2.7  SUPERVISORY Signals (Typical Connection) ................................................ 13 

CHAPTER 4:

 

POWER SUPPLIES CONNECTION ....................................................................... 14

 

4.1  Parallel Operation .................................................................................................... 14 
4.2  Series Operation ....................................................................................................... 15 

CHAPTER 5:

 

PMBus INTERFACE............................................................................................ 16

 

5.1  HFE1600/S Series I

²

C Specification .......................................................................... 16 

5.1.1  PMBus Interface ......................................................................................... 17 

5.1.2  HFE1600 May Have Optional Power Management Bus Hardware ............ 17 

5.1.3  Addressing (A3, A2, A1, A0 Inputs) ............................................................. 17 

5.1.4  Serial Clock .................................................................................................. 17 

5.1.5  Serial Data ................................................................................................... 17 

5.1.6  SMB Alert .................................................................................................... 18 

5.1.7  PMBus Typical Connection ......................................................................... 18 

5.2  PMBus Command Set ............................................................................................... 19 

5.2.1  Read Status ................................................................................................. 19 

5.2.2  Clear Faults ................................................................................................. 19 

5.2.3  Operation (ON/OFF) ................................................................................... 19 

5.2.4  Commands to Read Inventory Details ........................................................ 19 

5.3  Programming and Monitoring Functions ................................................................. 20 

5.3.1  Monitoring Output Voltage (READ_VOUT) ................................................. 20 

5.3.2  Monitoring Output Current (READ_IOUT) .................................................. 21 

5.3.3  Monitoring Supply Temperature (READ_TEMPERATURE_1) ..................... 21 

5.3.4  Programming Output Voltage (VOUT_COMMAND) ................................... 21 

5.3.5  Programmable Maximum Output Voltage (VOUT_MAX) ........................... 22 

5.3.6  Enabling / Disabling Monitoring Filter ........................................................ 22 

 

Содержание HFE1600/S series

Страница 1: ...3 3 2 7 SUPERVISORY Signals Typical Connection 13 CHAPTER 4 POWER SUPPLIES CONNECTION 14 4 1 Parallel Operation 14 4 2 Series Operation 15 CHAPTER 5 PMBus INTERFACE 16 5 1 HFE1600 S Series I C Specifi...

Страница 2: ...ac 105 120 of rated output current 26 Over voltage protection 10 V Tracking OVP range 1 1xVout accuracy 3 refer to Instruction Manual 27 Over temperature protection Inverter shut down method automatic...

Страница 3: ...als of the HFE1600 S1U 8 Voltage drop on load wires HFE1600 12 0 25V wire HFE1600 24 0 5V wire HFE1600 32 0 75V wire HFE1600 48 1V wire 9 Accuracy applicable for load current 50 of rated output curren...

Страница 4: ...32Vac 100Vac 85Vac 26A 31 5A 37 5A 39A 47A 265Vac 170Vac 132Vac 100Vac 85Vac 34A 42 5A 50A 56A 67A 265Vac 170Vac 132Vac 100Vac 85Vac 85A 91A 100A 121A 133A 265Vac 170Vac 132Vac 100Vac 85Vac 1584W Max...

Страница 5: ...c 170Vac 132Vac 100Vac 85Vac 1280W 265Vac 170Vac 132Vac 100Vac 85Vac 1200W 265Vac 170Vac 132Vac 100Vac 85Vac 880W 265Vac 170Vac 132Vac 100Vac 85Vac 825W 265Vac 170Vac 132Vac 100Vac 85Vac 550W 550W HFE...

Страница 6: ...5 1 3 HFE1600 Outline Drawing...

Страница 7: ...by Voltage Refer to Section 3 2 5 and Section 3 2 6 SENSE B9 SENSE Positive sense The SENSE signal should be connected to V on Power Supply or Load side SENSE B11 NOT CONNECTED B12 INHIBIT Turns OFF...

Страница 8: ...durch TDK Lambda zugelassen POWER SYSTEM OVERVOLTAGE CATEGORY ENVIRONMENTAL CONDITIONS The HFE1600 xy units have been evaluated for using inTT and IT 230VAC line to line power systems The HFE1600 xy u...

Страница 9: ...re touching Heisse Oberfl chen WARNUNG ImDauerbetrieb erw rmen sichdieGeh useoberfl chen UmdasVerletzungs Risikodurchheisse Oberfl chen zu minimieren sollte das Ger t einige Zeit abk hlen k nnen bevor...

Страница 10: ...hren Direct current DC Gleichstrom DC Alternate current AC Wechselstrom AC Denotes hazard A procedure requires specific attention Not following the procedure correctly could result in a personal injur...

Страница 11: ...ut Voltage Vin is below 85Vac or above 270Vac Figure 3 1 Front Panel Indicators CAUTION When inserting a power supply into the rack do not use unnecessary force Slamming the power supply into the rack...

Страница 12: ...tion Remote Sense SENSE have to be connected to the V terminals on the Load side prior to operating the supply ENABLE input must be connected to SIGNAL RETURN in order for the supply to turn on Figure...

Страница 13: ...t Voltage Programming by External Voltage Output Voltage of HFE1600 Series can be programmed by external voltage source between approximately 80 120 for 24V 32V 48V and 80 110 for 12V of nominal outpu...

Страница 14: ...xed to 5V but variable Figure 3 8 Programming by PMBus 3 2 7 SUPERVISORY Signals Typical Connection The following supervisory signals are accessible DC OK AC FAIL PS EXIST TEMP ALARM Figure 3 9 Signal...

Страница 15: ...ow N 1 operation If Voltage programming is used Voltage Programming Pin of all units must be connected in parallel Referenced to SIGNAL RETURN floating from the output controls signals and 12V AUX can...

Страница 16: ...to Load point or to V and V accordingly for Local Sense In case PMBus is used Connect PMBus signals in parallel PMBus is isolated from Output and choose different address for each unit see chapter 3 O...

Страница 17: ...OUTPUT CURRENT MEASUREMENT HFE1600 12 S HFE1600 24 S HFE1600 32 S HFE1600 48 S 4 1 Measurement accuracy 1 10 of full scale 4 2 Measurement resolution 10 bit 4 3 Measurement range Full Scale Only for...

Страница 18: ...Significant Bits A6 A5 A4 always equals 001 Variable part of address consists of 4 Least Significant bits A3 A2 A1 and A0 Value of these four bits have to be assigned by hardware connections of 4 pins...

Страница 19: ...sistor This Signal is HIGH to indicate that no fault error is present If some fault error occurs the signal will go LOW The Host system must poll multiple supplies after receiving SMBALERT to retrieve...

Страница 20: ...tput ON Command Error WARNING 7 Command not understood by Power Supply 2 Output ON 1 If Max Allowed Voltage is set to 48V and Programmed Voltage is set to 50V Output will be programmed to 48V Bit No 6...

Страница 21: ...onitoring A 0 160 6394 0 3 Temperature monitoring 0 100 1023 0 2 Table 5 1 Coefficients Table m b R coefficients can also be recovered from the EEPROM Coefficients are stored in ASCII Format Command N...

Страница 22: ...rature reading is 3 The read back supply temperature can be calculated using the Direct data Format Please refer to Table 5 1 for the Coefficients for calculating the Supply Temperature Command Used T...

Страница 23: ...the Voltage Programming Command Used Type Data Bytes 24h R W Word 2 Example Power Supply HFE1600 24 To program the maximum programmable output voltage to 29V Send 853x29 15360 10 938 DEC 5 3 6 Enabli...

Страница 24: ...23 This page intentionally left blank...