CHAPTER 7
RS-232 & RS-485 REMOTE CONTROL
7.1
INTRODUCTION
This chapter describes the operation of the Genesys
TM
2400W power supplies via the serial communication port.
Details of the initial set-up, operation via RS-232 or RS-485, the command set and the communication protocol
are described in this chapter.
7.2
CONFIGURATION
Default setting
7.2.1
The power supply is shipped with the following settings:
-
Address
:
6
-
Output
:
Off
-
Baud rate
:
9600
-
Start-Up
mode
:
Safe-Start
-
RS-232/RS-485
:
RS-232
-
OVP
:
Maximum
-
Vout setting
:
0
-
UVL
:
0
-
Iout setting
:
Maximum
-
Foldback
:
Off
-
Master/Slave
H1 (Master)
-
Front panel
:
Unlocked (UFP)
Address Setting
7.2.2
The power supply Address can be set to any integer value between 0 and 30. Follow the instructions described
below to set the unit Address.
1. If the unit is in
Remote
mode (front panel
REM/LOC LED
illuminated), press the
REM/LOC
button to put the
unit into
Local
mode.
2. Press and hold the
REM/LOC
button for approximately 3 seconds. The
VOLTAGE
meter will display the
communication port Address.
3. Using the
VOLTAGE
adjust encoder, select the unit Address.
To preview the power supply Address at any time, press and hold the
REM/LOC
button for approximately 3
seconds. The
VOLTAGE
meter will display the power supply Address.
RS-232 or RS-485 Selection
7.2.3
To select between RS-232 and RS-485 serial communication, set the rear panel setup DIP-switch SW1-6
position to:
-
DOWN:
RS-232
-
UP
: RS-485
Baud Rate Setting
7.2.4
Five optional Baud rates are possible: 1200, 2400, 4800, 9600 and 19200. To select the desired Baud rate, the
following steps should be taken:
1. If the unit is in
Remote
mode (front panel
REM/LOC LED
illuminated), press the
REM/LOC
button to put the
unit into
Local
mode.
2. Press and hold the
REM/LOC
button for approximately 3 seconds. The
CURRENT
meter will display the
communication port Baud rate.
3. Using the
CURRENT
adjust encoder, select the desired Baud Rate.
To preview the power supply Address at any time, press and hold the
REM/LOC
button for approximately 3
seconds. The
VOLTAGE
meter will display the power supply Address.
Setting the Unit into Remote or Local Mode
7.2.5
1. The unit will be put into
Remote
mode only via serial communication command.
Commands that will put the unit into
Remote
mode are:
-
RST
-
PV n
-
OUT n
-
PC n
-
RMT n
(for “
n”
values see Tables 7-3, 7-4, 7-5, and 7-6)