TDK-Lambda DTM70 Series Скачать руководство пользователя страница 4

DTM70, DTM70-C8 Manual

 

External AC-DC Power Adapters, 70W 

 

All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless  
otherwise noted. The information presented in this document is believed to be accurate and reliable and may change without notice. 

For additional information, please visit 

https://product.tdk.com/en/power/dtm

 

4/13

DOC-ID: 260932 – Issue 1

5.  R

ECYCLING AND 

D

ISPOSAL 

I

NFORMATION 

 

The device may not be disposed of as domestic refuse. 
Packaging and packaging aids must be recycled or disposed in accordance with local regulations. 

6.  F

UNCTIONAL 

D

ESCRIPTION

 

The output is electronically protected against no-load, overload and short circuit. In case of an overload or 

short circuit, the device will operate intermittently (hiccup mode). 
The device can supply resistive and inductive loads. 
Avoid loads with large input capacitances. If the capacitive load is higher than the values specified, the device 

operates in an intermittent mode (hiccup mode). See short-form data table for maximum values. 
The output voltage is fixed and can not be adjusted. 
The device is equipped with an over-temperature protection. In case of a high temperature, the output shuts 

down and starts automatically after cooling off. 
The device is equipped with an input under-voltage protection. If the input voltage is too low, the device does 
not start or switches off. 
In case of an internal defect, a redundant circuit prevents the output voltage from becoming excessive or 

dangerous. 
The device is equipped with a green DC-OK LED, which is visible from the outside of the device. 

7.  F

UNCTIONAL 

D

IAGRAM

 

N

+

+

-
-

Output

Over-

Voltage

Protection

Power

Converter

Output

Filter

Output

Power

Manager

Input Fuses

Input Filter

Input Rectifier

Inrush Limiter

L

DC-OK

LED

3

4

1

2

N

Functional diagram DTM70

 

 

+

+

-
-

Output

Over-

Voltage

Protection

Power

Converter

Output

Filter

Output

Power

Manager

Input Fuses

Input Filter

Input Rectifier

Inrush Limiter

L

DC-OK

LED

3

4

1

2

Functional diagram DTM70-C8

 

Содержание DTM70 Series

Страница 1: ...Curves 7 11 EMC 8 12 Physical Dimensions Weight and Connectors 9 13 Environment 10 14 Isolation and Dielectric Strength 11 15 Safety and Protection Features 11 16 Approvals and Regulatory Compliances...

Страница 2: ...compact design achieved by the high efficiency and the standard locking DIN output connector which prevents unintentional output voltage disconnection Other connector versions and cable assemblies are...

Страница 3: ...he device is designed to operate in areas with a maximum relative humidity of 93 4 INSTALLATION INSTRUCTIONS Before operating this device please read this manual thoroughly and retain this manual for...

Страница 4: ...If the capacitive load is higher than the values specified the device operates in an intermittent mode hiccup mode See short form data table for maximum values The output voltage is fixed and can not...

Страница 5: ...70CN480 External Adapter Power Supply Class I 70W 48V 1 5A DTM70CN120C8 External Adapter Power Supply Class II 70W 12V 5 8A DTM70CN150C8 External Adapter Power Supply Class II 70W 15V 4 65A DTM70CN180...

Страница 6: ...90 and 264Vac Load regulation Max Max Max 5 3 2 For DTM70CN120 DTM70CN120C8 For DTM70CN150 DTM70CN150C8 For all remaining models For 60 40 load steps Ripple and noise voltage Max Max Max Max Max Max...

Страница 7: ...0CN120C8 Efficiency vs output load DTM70CN150 DTM70CN150C8 Efficiency vs output load DTM70CN180 DTM70CN180C8 Efficiency vs output load DTM70CN240 DTM70CN240C8 Efficiency vs output load DTM70CN360 DTM7...

Страница 8: ...les class 3 80Vac 250 300 cycles class 3 Criterion A Criterion A Criterion B Criterion A Criterion A Voltage interruptions EN 61000 4 11 EN 60601 1 2 AC 100 120 230Vac 0Vac 250 300 cycles class 3 Crit...

Страница 9: ...tor Kycon KPPx 4P or equivalent P1 P2 Vout P3 P4 Vout Alternative output connectors are available Please contact sales for further information minimum quantities apply All parameters are typical value...

Страница 10: ...rding to IEC 60664 1 Degree of pollution 2 According to IEC 62477 1 not conductive Vibration sinusoidal 4g 15 2000Hz 60 minutes per axis According MIL STD 810F Table 514 5C VIII sinusoidal vibration u...

Страница 11: ...70CN180 DTM70CN180C8 For DTM70CN240 DTM70CN240C8 For DTM70CN360 DTM70CN360C8 For DTM70CN480 DTM70CN480C8 In case of an internal defect a redundant circuit limits the maximum output voltage The output...

Страница 12: ...ical equipment Part 1 General requirements for basic safety and essential performance Part 1 6 Collateral standard Usability Part 1 11 Collateral Standard Requirements for medical electrical equipment...

Страница 13: ...ted The information presented in this document is believed to be accurate and reliable and may change without notice For additional information please visit https product tdk com en power dtm 17 PACKA...

Отзывы: