TDK-Lambda DRB120 Series Скачать руководство пользователя страница 1

PA620-04-xxx 

                                                                                                    

TDK-Lambda 

DRB120  Series 

                    

 

 

 

 

 

 

 

 

 

      

INSTRUCTION  MANUAL

 

PA634-04-02 
 

For further installation instructions refer to web link: 
emea.tdk-lambda.com/PA634-04-01_ 

 
 

  

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   BEFORE USING THE POWER SUPPLY UNIT 

 

Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, 

damage to the unit or a fire hazard. 

 

Warning Symbols 

CAUTION 

.

 DO NOT MODIFY OR DISASSEMBLE THE POWER SUPPLY. 

 

 

.

 

READ INSTRUCTION MANUAL BEFORE CONNECTING TO MAINS.

 

 

.

 

ELECTRIC SHOCK HAZARDOUS ON THE CONNECTOR SECTION.

 

 

  
   NOTICE: 

(1)

 

Installing/Storage Environment 

         1. Store the product with ambient temperature

 

–40 to +85 

°

C, and relative humidity 5 to 95% (No dewdrop). 

         2. Avoid operating the unit in over current, short circuit or out of input voltage range which could result in damage. 
         3. Confirm connections to input/output terminals are correct as indicated in the instruction manual.      
         4. Use the product where the relative humidity is

 

5 to 95% (No dewdrop). 

        

5. Avoid places where the product is subjected to direct sun light. 

        

6. Avoid places where the product is subjected to penetration of liquid, foreign substance or corrosive gas.  

         7. Avoid places subject to shock or vibration. 
             A device such as a contact breaker may be a vibration source. Set the power supply as far as  
             possible from any source of shock or vibration. 
         8. If the Power Supply is used in an area with excessive electronic noise, be sure to separate the 
             Power Supply as far as possible from the noise sources. 
         9. Don’t use the product in the environment with strong electromagnetic field, corrosive gas and conductive  
             substance. 
       10.

 

Model/type reference: DRB120-24-1-xyz (where xyz is optional and can be alphanumeric 

              characters or blank and it is not a safety related information - product ratings unchanged) 

   

Precautions in Using the product: 

      When the product is used under the circumstance or environment below, ensure adherence to limitations of  
       the ratings and functions. 
      Also take countermeasures for safety precautions such as fail-safe installations. 
         1. Under the circumstances or environment which are not described in the instruction manual. 
         2. For nuclear power control, railway, aircraft, vehicle, incinerator, medical equipment, entertainment 
         equipment, safety device etc. 
         3. For applications where death or serious property damage is possible and extensive safety precautions are required.                 
         4. Not to be used with a high inductive power source as it may cause unstable operation of the power supply. 

  Note: CE MARKING 

  CE Marking, when applied to a product covered by this handbook indicates compliance with the following: 
  Low Voltage Directive in that it is complies with EN60950-1. 

  EMC Directive  

  Restriction of the use of certain Hazardous Substances Directive  

       

 

DRB120 Series Instruction Manual 

Содержание DRB120 Series

Страница 1: ... from any source of shock or vibration 8 If the Power Supply is used in an area with excessive electronic noise be sure to separate the Power Supply as far as possible from the noise sources 9 Don t use the product in the environment with strong electromagnetic field corrosive gas and conductive substance 10 Model type reference DRB120 24 1 xyz where xyz is optional and can be alphanumeric charact...

Страница 2: ...ording to EN UL60950 1 multi strand flexible cables connected to the input require ferrule 3 Terminal Connecting Method Pay attention to the input wiring If it is connected to wrong terminal the power supply will be damaged Input must be off when making connections Connect Protective Earth terminal of input connector to ground terminal of the equipment The output load line and input line shall be ...

Страница 3: ...minute and then re apply Possible to hiccup if the unit prior to OVP point is already loaded The OVP point is fixed and cannot be adjusted externally 4 4 Over Current Protection OCP Hiccup mode with automatic recovery If the output current is 101 of peak load the unit will hiccup Avoid continuous operation in overload or short condition as it may result in damage to the power supply 4 5 Peak outpu...

Страница 4: ...hstand voltage set current limit of the withstand voltage test equipment to 20mA Output Protective Earth 100mA The applied voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high impulse voltage at timer switch on and off Connect input and output as followed Input Output dotted line 424...

Страница 5: ...um installation clearance 40mm on top 20mm on the bottom A 5mm which is recommended on the left and right side when products are permanently loaded with full 120W In case the adjacent device is a heat source A 15mm clearance is recommended 6 1 Power supply mounting on DIN RAIL TS35 or equivalent Make sure input and output wire disconnected when mount power supply onto rail 1 Tilt the unit slightly...

Страница 6: ...dance Noise can be eliminated by attaching a capacitor to the load terminals EMI reduction performance by winding the cable around a toroidal ferrite core several times Use any appropriate commecially available ferrite core from local vendor For safety and EMI considerations connect Protective Earth terminal of input connector to ground terminal of equipment 8 1 EMC DRB120 complies with the provis...

Страница 7: ...n accordance with the product specification 11 Before concluding that the unit is at fault Before concluding that the unit is at fault make the following checks Check if the rated input voltage is connected Check if the wiring of input and output is correct Check if the wire material is not too thin Check if the output voltage control V ADJ is properly adjusted Check if the output current and outp...