background image

 

Digalox

®

 DPM72 XBEE interface

Instruction manual (Rev-2022-08)

1. Description

The   Digalox

®

  DPM72   devices   with   XBEE   interface   can   communicate   with   other 

DPM72 devices via XBEE radio technology (2.4 GHz mesh network). In this way, 
measured values from remote devices can be integrated into a display as remote 
values. Using the radio interface the devices can also be configured individually. 
The mesh network offers a robust connection that ensures continued operation even 
if a single radio node fails. Each additional node acts as a router, increasing the 
range of the network.

2. Specification

2.4 GHz (IEEE 802.15.4) mesh network

Radio module: XB3-24Z8UM-J
(Digi XBee 3 Zigbee 3.0, 2.4GHz, Micro, U.FL Ant, MMT)

Antenna connector: SMA

Range between two radio nodes: up to 60 m indoors, up to 1200 m outdoors 
with a clear line of sight

3. Connections

-----

 1 / 4 

-----

Содержание Digalox DPM72

Страница 1: ...he radio interface the devices can also be configured individually The mesh network offers a robust connection that ensures continued operation even if a single radio node fails Each additional node acts as a router increasing the range of the network 2 Specification 2 4 GHz IEEE 802 15 4 mesh network Radio module XB3 24Z8UM J Digi XBee 3 Zigbee 3 0 2 4GHz Micro U FL Ant MMT Antenna connector SMA ...

Страница 2: ...ordinator must be assigned to one device The coordinator starts and manages the network There can only be one coordinator and it must be active at all times The other devices should receive the XBEE role Router They can connect to a started network and integrate other devices Using the XBEE remote values tab 4 remote values can be read from other devices In order to display these remote values the...

Страница 3: ...tus display The state of the communication is shown on the display Display Description Status Symbol flashes Network is being configured Symbol shines Network connected Crossed out symbol shines Network disconnected C C Coordinator shines XBEE Role Coordinator R R Router shines XBEE Role Router M M Master flashes Device communicates in master mode requesting values from others S S Slave flashes De...

Страница 4: ...address If necessary read the transmit status number in the XBEE3 documen tation XB response slavecom_stat S x Slave x responds with error message slavecom_stat 0 OK 1 Uninitialized 2 Invalid command 3 Invalid status 4 Invalid CRC 5 Invalid slave 6 Invalid interface 7 Communication failed 8 Buffer overflow 9 Invalid address 10 Device failure 11 Device busy 12 Gateway path unavailable 13 Gateway ta...

Отзывы: