Fail-Over Port Configuration Via CLI

NOTE: 

Configuring the Gateway in this manner requires a working knowledge of text-based user interfaces. Do not 

attempt this method of configuration if you are unfamiliar with text-based user interfaces.

1. 

Connect a keyboard and monitor directly to the QWL2040 Panel and reboot the device (See 

Appendix C: Monitor and 

Keyboard on page 26

).

2. 

Establish a connection to the CLI (see

 

Gateway Configuration via CLI on page 15

).

3.  Skip past the setup questions until you see the Failover settings. 
4.  Enable Failover by entering a “1”.

5.  In the Host Name field, enter the host name provided by your IT department.

6. 

Skip to the Local Ethernet 2 fields. Enter the failover network information provided by your IT department.

7.  Exit the CLI to save settings. Disconnect the monitor and keyboard. Do not reboot the QWL2040 Panel.

Changes made via the CLI will take about five minutes to execute.

Содержание QWL2040

Страница 1: ...2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com 202403 Building Automation Systems Building Automation Systems Installation Manual QWL2040 Panel Integrated Building Manager...

Страница 2: ...et 14 No Communication with RS485 Ports COM 1 and 2 Ubiquity Time out or No Data 14 Gateway Configuration 16 Introduction to Gateway Configuration 16 Gateway Configuration Via Laptop 16 Gateway Config...

Страница 3: ...installation of the unit Gateway Configuration Most Panels come with the Gateway preconfigured if your Panel was preconfigured by TCS you can skip this section However some customers order their Panel...

Страница 4: ...nt being controlled by the relay EEMS Enterprise Energy Management System A system of computer aided tools used by operators of electric utility grids to monitor control and optimize the performance o...

Страница 5: ...plication programs can exchange data TCP IP Transmission Control Protocol Internet Protocol A set of standardized rules that allow computers to communicate on a network such as the internet UI User In...

Страница 6: ...es with a one inch wiring access port pre drilled in the top of the unit Drilling into the unit to add additional wiring access ports is at your own risk Use caution when drilling into the unit be sur...

Страница 7: ...estart the unit Exterior views Cloud Connectivity Ethernet Port Connect an Ethernet cable to the Ethernet port on the side of the Panel Connect the other end of the cable to your network switch port a...

Страница 8: ...to the inputs on Com Port panel or on the Serial Board adjacent to the Gateway see RS485 Controller Network Wiring Setup on page 10 USB Ports 1 4 As an option you can connect up to 64 RS485 controlle...

Страница 9: ...owing components Ubiquity Cloud Gatewayr SLQ218 Lighting Controller SLQ100 Electrical Pulse Meter These components accept the following inputs SLQ218 Lighting Controller Eight dry contact digital inpu...

Страница 10: ...rough the network On controllers with displays this can be done from the controller using its keypad and display by using TCS Insight software or by calling TCS Technical Support 800 288 9383 ext 2 TC...

Страница 11: ...ors contact TCS Technical Support 800 288 9383 ext 2 Three Wire Network Wiring Follow this wiring diagram for all three wire systems this is common NOTES In the middle of the network all network wirin...

Страница 12: ...ontrollers use the second RS485 port or additional QD1010 adapters 2 Each controller must use the same baud rate and be assigned a unique address Two Wire Network Wiring Follow this wiring diagram for...

Страница 13: ...o a cell modem if utilized 4 Connect the power source to the QWL2040 Panel and apply power If your Panel was preconfigured by the TCS factory or another user it will automatically go online and contac...

Страница 14: ...ollow polarity Make sure the A wire goes to the A terminal in all devices as well as the wires that go to B and REF terminals No LAN Link to the Internet Verify the network cable is connected correctl...

Страница 15: ...ting the serial ports are operational is located inside the enclosure on the Ubiquity Cloud board If none of these lights are functioning Ubiquity Cloud is not coming online This could be because the...

Страница 16: ...t is the customer s responsibility to configure a custom login and password Contact TCS Technical Support 800 288 9383 ext 2 for information on managing Gateway login credentials Gateway Configuration...

Страница 17: ...lect a Network Polling Cycle Time for the Panel This is the time interval that the unit will poll the entire network of controllers on all ports You must select whether to allow caching the host name...

Страница 18: ...elect the communications protocol being used on each port TCSbus is selected by default Baud Rate This is the data transmission speed on the network The Baud Rate must be the same selection for the po...

Страница 19: ...ly assigned when communication is established MTU Adjustments Adjusting the MTU down may allow gateways to communicate with smaller TCP packet sizes This may be useful if you are using cell modems not...

Страница 20: ...mation Commissioning Tools You can access a separate page containing various commissioning tools by clicking the Commissioning Tools button at the bottom of the Security Information page These tools p...

Страница 21: ...on the right side of the Controller View title bar will refresh each controller s status System Commands This section describes how to set up system flags for the Panel Reboot Unit sets a flag which...

Страница 22: ...22 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 22 Gateway Configuration Command Line Interface Screens Gateway configuration Application options...

Страница 23: ...23 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 23 Gateway Configuration Proxy options Extended application options...

Страница 24: ...ely be prompted to change your login credentials Ubiquity Cloud login screen Lighting Module Programming Channel Event Scheduling The lighting module is equipped with eight independent event channels...

Страница 25: ...GND To use this input with a threshold and hysteresis Channel Power section to shut off lighting channels select the relevant lighting channels Enable AI2 Threshold checkboxes and enter a threshold an...

Страница 26: ...l Time NOTE For non North American Daylight Saving Time set the manual DLS Day Light Saving Time Channel Occupant Override A good example of the use of this feature is to allow for a cleaning crew to...

Страница 27: ...demand for that particular meter For each of the four SEQ100 meter inputs there are five selectable options 1 ELEC 1 PH Electric single phase meter 2 ELEC 3 PH Electric three phase meter 3 GAS Gas me...

Страница 28: ...and is set to 1 PPR Value The value of the PPR is the number of pulses per 1 kWh 1 BTU 1 gallon minute For example one pulse per 1 kWh equals 10 pulses per 1 kWh so the PPR value is set to 10 Constant...

Страница 29: ...nterface Card NIC 2 Ethernet cable Connection Setup Ethernet Cable Connect one end of the Ethernet cable to the Local Management Ethernet Port on the Panel see Power and Communication Connections on p...

Страница 30: ...ange adapter options 3 On the Network Connections panel locate the Ethernet interface that is connected to the cable Right click on the item and select Properties Properties 4 On the Ethernet Properti...

Страница 31: ...31 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 31 Appendices TCP IPv4...

Страница 32: ...ing Automation Systems 32 Appendices 5 On the Internet Protocol Version 4 TCP IPv4 Properties change the IP schema to IP Address 10 248 248 2 Subnet Mask 255 0 0 0 Default Gateway 10 248 248 2 DNS Bla...

Страница 33: ...Systems 33 Appendices 7 Launch any web browser and type in the following address https 10 248 248 1 Device address 8 Depending on your browser s configuration you may get the following screen Privacy...

Страница 34: ...ys com Building Automation Systems 34 Appendices 10 Click on the Proceed link to take you to the next screen Proceed screen 11 Enter the Login user name and password Login screen 12 Configure the Gate...

Страница 35: ...ement Port on page 29 and wish to revert back to its previous configuration follow the steps below Windows 10 or Later 1 Search for Ethernet Settings and click the Open link Ethernet settings 2 On the...

Страница 36: ...WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 36 Appendices Properties 4 On the Ethernet Properties panel locate the Internet Protocol Version 4 TCP IPv4 Select that option then c...

Страница 37: ...37 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 37 Appendices TCP IPv4...

Страница 38: ...utomation Systems 38 Appendices 5 On the Internet Protocol Version 4 TCP IPv4 Properties General tab 6 Click on the Obtain an IP address automatically radio button 7 Click on the Obtain DNS server aut...

Страница 39: ...ct the cable to the monitor and to the Panel Gateway matching up the corresponding ends HDMI DP See Power and Communication Connections on page 7 Power on the monitor and switch to the proper input ba...

Страница 40: ...Command Line Interface CLI by connecting a keyboard and monitor to the device See Appendix C Monitor and Keyboard on page 26 Hardware Internet Requirements You must provide a secondary Internet connec...

Страница 41: ...mmends contacting your IT department before making any changes to the default settings Click on the green Update Application Info button beneath the RS485 Network Port Configuration section to save th...

Страница 42: ...he QWL2040 Panel and reboot the device See Appendix C Monitor and Keyboard on page 26 2 Establish a connection to the CLI see Gateway Configuration via CLI on page 15 3 Skip past the setup questions u...

Страница 43: ...43 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 43 Appendices Failover URL Settings E port 2 mode settings...

Страница 44: ...Insight software you will need Laptop PC running Windows 10 or later with an available USB port USB A to B Cable RS485 Cable QD1010 USB Converter wired networks OR QW1010a Converter wireless networks...

Страница 45: ...e Insight software and select Install FTDI Driver Follow the installation instructions 5 Select the new COM port and click on the Open Port button 6 Click on the second Poll tab This will cause the so...

Отзывы: