11/2012
9
TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
PI_ISH3022-uk
Connection diagram 2-wire technique
Connection diagram 3-wire technique
Note: Replace an ISH1030 or TTS1 with an ISH3022
The floor push button always has to be connected to the a-wire.
In case of a parallel connection, both telephones must be replaced with an ISH3022.
Commissioning
Install the devices of the system voltage-free and completely.
Check the a-, b- and P-wire against each other for short-circuits.
Switch on the mains voltage.
Note:
If the floor push button does not work, check if it is connected to the a-wire of the power
supply and control unit.
Settings
2-wire/3-wire operation
Ex works, the jumper J1 is configured for
2-wire operation .
J1
2-wire operation (delivery state)
Plug the jumper J1 on the two upper contacts for
3-wire operation.
3-wire operation