background image

11/2012 

 

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129 

 

PI_ISH3022-uk 

 

Max. number of ISH3022 in 2-wire operation 

when using power supply 
and control unit 

max. number 

ISH3022 

 

BVS20 or  
NBV1000, 1 strand 

20 

BVS100,  
distributed on 3 strands 

80 

PSG02, 1 strand 

30 

 

Max. number ISH3022 in 3-wire operation 

when using power supply 
and control unit 

max. number 

ISH3022 

 

BVS20 or  
NBV1000, 1 strand 

20 

BVS100,  
distributed on 3 strands 

80 

PSG02, 1 strand 

90 

BVS20 + NGV1011,  
1 strand 

90 

AS  front-door station 
VS  power supply and control unit 
IS  indoor station 
Note: The max. number of front-door stations that can 
be connected is limited. Also described in the respec-
tive product information!

 

NGV1011,  
3 strands 

270 

 
 
 

Short description 

 

  large, blue door release button 

  ring tone volume can be adjusted continuously by a qualified electrician  

  acoustic ring tone distinction: door call from 2 front-door stations, call from the flat door 

(floor bell) and internal call (ring tones are set) 

  one parallel call can be adjusted with the Service Device TCSK-

01 or configo™ 

  audio privacy function 

  pluggable handset cord 

  lower cover with plugged screw terminal can be pre-installed 

  configuration 

software configo™ can be used for comfortable system configuration at 

PC with automatic detection of device types and serial number 

  extendable with call relay, triggering of radio signal device, 

  energy efficient through low standby consumption of only 0.01 W 

  2-wire technique which is easy to modernise, 3-wire technique possible 

  tested according to EN 50486 

  housing made of antistatic and recycable plastics 

Содержание ISH3022

Страница 1: ...TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISH3022 uk Product information Door telephone ISH3022...

Страница 2: ...ended functions 7 Connect the lines 8 Connection lines 8 Wiring example 8 Connection diagram 2 wire technique 9 Connection diagram 3 wire technique 9 Note Replace an ISH1030 or TTS1 with an ISH3022 9...

Страница 3: ...ding to DIN VDE 0100 must be observed When installing TCS BUS systems the general safety regulations for telecommunication systems according to VDE 0800 must be observed separated conduit of heavy cur...

Страница 4: ...s put down if the light switch function is activated in the front door station Intended use The ISH3022 is an indoor station for duplex communication As door telephone it is suitable for the operation...

Страница 5: ...product information BVS100 NGV1011 3 strands 270 Short description large blue door release button ring tone volume can be adjusted continuously by a qualified electrician acoustic ring tone distinctio...

Страница 6: ...ews to the wall Connect the lines Minimise the length of the lines above the upper cover to place the lines without any problems and do not clamp the lines when snapping on the upper cover Connect the...

Страница 7: ...evice Insert a small screwdriver straight and with slight pressure into this opening The upper cover can be removed at the underside 1 Lift the upper cover out of the two upper adjustment increments 2...

Страница 8: ...t the lines Connection lines acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact each 2 x 0 8 mm 3 x 0 6 mm Further wires have to be connected with aux...

Страница 9: ...tion both telephones must be replaced with an ISH3022 Commissioning Install the devices of the system voltage free and completely Check the a b and P wire against each other for short circuits Switch...

Страница 10: ...sion 1 3 3 ring tone volume x parallel allocation x x reload to factory setting x Programming with the Service Device TCSK 01 The indoor station is acting as a telephone Use the commands 8 for configu...

Страница 11: ...wer supply optional strand or star formed wiring Table loop resistances Line length in m Line diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 50 6 38 3 57...

Страница 12: ...0 2 mA I P 0 2 mA max input current I Pmax 60 mA Repair Replace the indoor station program bell buttons Basic principle All devices at the TCS BUS have a unique serial number Programming a bell butto...

Страница 13: ...d shortly press LED is on programming mode of the system is switched off a Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there soun...

Страница 14: ...mbol shows that the device has to be disposed separately from domestic waste The materials used are recyclable Please do help protecting our environment and dispose the device via a collection point f...

Страница 15: ...11 2012 15 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISH3022 uk...

Страница 16: ...de Subject to technical changes FAX 49 0 41 94 9 88 129 PI_ISH3022 uk Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str...

Отзывы: