background image

TCS TürControlSysteme AG, TCS Hotline Germany:  +49 41 94/ 9 88 11 88

 

Subject to technical changes. 

FAX: +49 41 94/ 9 88 129  

  Mail: [email protected]

 

PI_IMM2500     1A 

 

 

 
 

Product information 

 

Indoor station with special functions 

for hands-free talking  

IMM2500

 

 

 

Содержание IMM2500

Страница 1: ...e AG TCS Hotline Germany 49 41 94 9 88 11 88 Subject to technical changes FAX 49 41 94 9 88 129 Mail hotline tcsag de PI_IMM2500 1A Product information Indoor station with special functions for hands...

Страница 2: ...otes on voltage supply 12 Wiring diagram 12 Connection diagram 12 Notes on LSA terminal points 12 Commissioning 13 Settings 13 Factory settings 13 Button assignment 13 Pre adjusted times 13 Set the ri...

Страница 3: ...24 Labelling the function keys 24 Cleaning 25 Conformity 25 Information on disposal 25 Warranty 25 Accessory 26 Build in a radio receiver board 26 Conformity 26 Information on disposal 27 Warranty 27...

Страница 4: ...avy and low current lines within shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter already existing lines modernisation with deviating cross sections can be...

Страница 5: ...table for the operation within TCS audio systems and combined audio video systems The IMM2500 is suitable for surface mount With a desktop accessory the indoor station can be operated on a desk Short...

Страница 6: ...e article number 0022932 Surveillance functions motion sensor to detect longer breaks in activity sends control function after a deter mined period of time 15min 63h can be deactivated sensitivity can...

Страница 7: ...ire operation I a 0 42 mA I P 12 2 mA max input current I Pmax 87 7 mA 3 wire technique necessary indication call OFF red LED indication additional functions green LED door release button function key...

Страница 8: ...F red ON call OFF is activated Blinks indication speech channel is busy door release button open the door trigger light switch function if light switch function is ac tivated in the front door station...

Страница 9: ...control function 9 is sent automatically after the de termined period of time has run out When in stalling the IMM2500 on a desktop accessory the motion sensor must be deactivated off door call signa...

Страница 10: ...round Install the lower cover Position the lower cover of the device with the cable gland over a flush mount socket Install the lower cover via the attachment holes 5 with suit able screws to the wall...

Страница 11: ...push button must be at least 1 second Snap on the upper covers of the modules 1 Place the upper cover at both adjustment in crement of the lower cover 1 2 Place the handset cord correctly within the...

Страница 12: ...voltage supply For supply a VBVS05 is to be used Max 5 indoor stations can be connected to the VBVS05 To supply more than 5 devices additionally a NGV1011 must be used To supply large systems NBV3200...

Страница 13: ...hannel is busy when pressing the speech button 3 sec 6 x blinking internal standby time around 2 min if the device was called around 30 seconds if the device itself is calling and waiting for call acc...

Страница 14: ...around 8 sec Both LEDs are ON and an acknowledgement tone sounds the ring tone selection is activated By pressing the following buttons a ring tone can be selected You can choose be tween 13 tones 7...

Страница 15: ...he basic and special function module is realised in 4 steps 1 2 3 4 Initiate the programming Function selection Allocation to button End the programming Initiating the programming is only necessary on...

Страница 16: ...tton an acknowledgement tone sounds shortly and the green LED expires Door release automatic Call diversion basic module Note Before programming the call diversion the AS address of the front door sta...

Страница 17: ...tion with programming func tion reload basic set ting Execute at the required indoor station lift the handset or press the speech button or Select door call 2 Block ring tone selec tion Block extended...

Страница 18: ...f no button is pressed for 30 seconds Programming the special functions By programming the button the prior function is overwritten automatically A previous deletion of the button is not necessary The...

Страница 19: ...l function 8 on GREEN o o o RED RED YELLOW GREEN Internal call 3 on RED Internal call 2 on YELLOW Internal call 1 on GREEN x x x YELLOW RED YELLOW GREEN Acoustic room surveillance on RED Switching lig...

Страница 20: ...pecial function module Press the button GREEN longer than 4 sec until only the indication for but ton GREEN blinks Press the button GREEN longer than 4 sec again The basic setting is re loaded All ind...

Страница 21: ...n module is in training mode Train radio sensor 4 sec Shortly press the button of the radio sensor which should be trained Indication for button RED is ON for around 4 sec then blinking again Shortly...

Страница 22: ...e s p e c i a If a trained radio sensor is operated the special function module always sends the programmed function of the button RED independently from a de activated room surveillance Programming...

Страница 23: ...sion to TKI and PFS can be realised Select door call signalling by motion sensor Several bright LEDs are positioned below the lens system of the motion sensor Factory setting Indication and operating...

Страница 24: ...pports this function in systems with PC central or PFS By pressing one of the configured buttons RED YELLOW GREEN a control function is sent The call is signalled in the central The central calls back...

Страница 25: ...ions of conformity for download under www tcsag de Downloads trade information Information on disposal The adjoining symbol shows that the device has to be disposed separately from domestic waste The...

Страница 26: ...ard is located on the PCB within the upper cover of the module with special functions Slide the contact pins of the radio receiver board into the designated socket position see adjoining illustration...

Страница 27: ...als used are recyclable Please do help protecting our environment and dispose the device via a collection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboar...

Страница 28: ...ensure a correct operating Introduce the customer to the operation of the devices of the system We also recommend the documentation of the door communication system Please check the configured functi...