 Enter / change SIP settings 

  Register under 

Settings 

VoIP

  Select 

SIP settings

 in the 

navigation bar. 

  Enter here the necessary 

data for your SIP server / 
telephone system, which 
you have determined during 
the registration of the 
FBI610x.  

  Click 

Save

 
Note for user name: 
This field is used only for information and 
does not have a special function. You 
can enter e.g. the position of the fron-
door station. 

 

 

!

 

The Reset button

 

resets the content to the latest stored data state. It does not reload 

the factory settings. 

 
 
 

SIP  
registration 
 

Displays, if the SIP-Gateway should register at the SIP-Server.  
If this option is not activated, only direct connections (peer to peer) can be realised. Thus, 
the IP-address of the SIP-device, that is to be called, must be entered in the phonebook. A 
connection via call numbers cannot be realised. 

SIP server 
and SIP  
server port 

Enter the IP-address or URL of the SIP providers / SIP server. The port number shows to 
which port the server belongs. 

SIP domain 

The SIP domain is used to identify devices and to establish a connection. Thus, the num-
ber is used within the SIP protocol (e.g[email protected]). Without the domain no connec-
tion via call number can be realised. Instead of a name also the IP-address of the SIP 
server can be entered. 

SIP server as 
outbound 
Proxy 

Use the SIP server as proxy for outgoing calls. The SIP server has to support this function. 
Thus, calling can be realised through a NAT firewall. 

DNS SRV 

Use the DNS server entry to call a device within the SIP domain. 

SIP  
User ID 

The user ID is the ID within a SIP domain. The ID is used to identify the SIP-Gateway. In 
case of an incoming call the allocation is realised via the user ID. A caller transmits the call 
request as 

“<Call number>@sipdomain.de“ or as “<User-ID>@sipdomain.de“. 

SIP authenti-
fication ID  

User name to register at the SIP server. 

SIP authenti-
fication PIN 

Password to register at the SIP server. 

user name 

The user name field is only for your information. It has no special function. Here you can 
enter e.g. the position of the front-door station. 

 
 
 
 

Содержание FBI6100-0400

Страница 1: ...ysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Product information SIP Gateway for 115 call destinations FBI6100 0400 for 10 call destinatio...

Страница 2: ...repare the intranet connection 8 Example network setup under Windows XP 9 Establish a network connection for configuration 10 Enter change IP address 11 Change the password 11 Enter change SIP setting...

Страница 3: ...lines within shared cable ducts use of standard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop...

Страница 4: ...tch unit max permitted contact load capacity of 24 V DC 1 A staircase light control unit FNA1000 or TZ1 SG with 8 24 V AC relay adjustable light switch time 0 to 99 sec adjustable function via web int...

Страница 5: ...0 output voltage idle state U a b 24 V 1 V U b P 26V 1V output voltage speaking U a b 22 V 1 V output current I a 40 mA max output current I Pmax 180 mA operation mode PASSIVE supply voltage 26 V 8 po...

Страница 6: ...VE or ACTIVE potential free relay contacts closing contacts to control automatic light switch units door opener single speech channel Communication from front door and indoor stations to more than one...

Страница 7: ...2014 7 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Wiring example operation mode ACTIVE Wiring example operation mode PASS...

Страница 8: ...eck the network check data transmission check login data for SIP server device is in standby mode again Network error defective network connection or no connection to the SIP server 4 error indication...

Страница 9: ...ord Network setup Example network setup under Windows XP Open the Network and data telecommunication connections in one of the following methods 1 Click with the right mouse button on the icon Network...

Страница 10: ...ablish a connection from the PC Laptop to the SIP Gateway via switch or router Alternatively connect the SIP Gateway directly to a PC Laptop via a crossover cable twisted pair cable Open an internet b...

Страница 11: ...Confirm with Save If the IP address was changed manually the web browser can possibly no longer dis play the page with the feedback If this is the case enter the new IP manually into the browser to g...

Страница 12: ...e IP address or URL of the SIP providers SIP server The port number shows to which port the server belongs SIP domain The SIP domain is used to identify devices and to establish a connection Thus the...

Страница 13: ...l characters serial number TCS BUS serial number which is to be programmed at the front door station The serial num ber has max 6 digits Shorter serial numbers are entered and displayed without leadin...

Страница 14: ...n the programming mode of the system In the operation mode ACTIVE Shortly press the RUN PROG button at the FBI610x or in the operation mode PASSIVE Shortly press the RUN PROG button at your power supp...

Страница 15: ...ton 7 must be pressed to accept the call The controlling of the FBI610x is realised via the MFV dial of the connected telephone Call from a telephone to a front door station A telephone can establish...

Страница 16: ...tory setting yellow LED lights up yellow LED blinks yellow LED blinks fast yellow LED lights up Press RUN PROG button and hold it keep RUN PROG button pressed until LED blinks then release factory set...

Отзывы: