20
internal call
control function 8
light switch function
parallel allocation
Note:
Deactivation of the parallel alloca-
tion corresponds to the parallel alloca-
tion to serial number 0.
ser. no. = the serial number of the indoor station that is to be configured new
TarSerNo. =
the serial number of the indoor station, to which the call is to be diverted
IntSerNo. = the serial number of the indoor station, which is to be called internally
ParSNo. = the serial number of the indoor station, to which the new configured indoor station
is allocated
General information on the OSD menu
The navigation within the OSD menu, the image buffer
a)
indication and
live image are realised via the navigation buttons UP and DOWN.
The OSD main menu can be activated when no live image is displayed
and if the indoor station is in standby mode. That means that no voice
connection is established and no door call has come in.
Symbols in the ODS menu are only displayed when the specific func-
tion was configured. In delivery state, not all possible functions are
configured.
The live image is activated by pressing the image button or the speech
button or when receiving a door call.
The OSD menu or image buffer
a)
indication is deactivated automatical-
ly after 10 sec, if no button is pressed. Or: Press the function key to ex-
it the menu.
The live image is deactivated automatically after 80 sec without any
activity, by ending the voice connection or when a video channel is
used by another device (not in case of a voice connection).
a)
only if an image buffer (FVM1000) is installed