Adjust length of lines in systems (long lines)
a) factory preset
Activate infrared remote control
►
Remove the battery cover on the back of the infrared remote control.
►
Remove the foil strips.
►
Replace the battery cover.
Initial operation
►
Install the devices of the system completely.
►
Proof the a-, b- and P-wire against each other on short-circuits.
►
Switch on the mains voltage.
Error detection and indication
Errors are signaled acoustically and optically: one error tone and constant flashing of the operation indi-
cation.
The optical error indication stays active until the error is fixed.
error cause
indication
error mode
error tone solution
a- and P-wire interchanged or
short circuited
LED
flashes
orange
change a- and P-wire or remove short-circuit, de-
vice goes into stand-by mode again
a-wire: not connected or not
supplied
connect a-wire or check power supply, device
goes into stand-by mode again
Sabotage contact activated:
control function 199 with own
serial number for “silent alarm”
is sent
insert nameplate correctly
Settings
Sabotage contact
When the sabotage contact is activated, a protocol is sent and an error message is displayed (LED
flashes orange). A control function with its own serial number is sent. If the device is properly closed
again, full functionality is restored.
► Configure the control function number using the configuration software configo™.
Requirement: Front-door stations and power supply
and control units connected to the system, must be
suitable for systems with a loop resistance of up to 60
Ohm.
►
Remove the plastic plate.
►
Set switch 2 to ON, in order to use a line resistance Zs up to 60
Ohm.
switch 2
lines
long
(Z
s
≤
60 Ohm)
normal
(Z
s
≤
20 Ohm)
a)
Fig. 8: DIP-switch 2