background image

Contact TCRS at 440-658-2020

 

Universal Warning

 

 

 

Do not operate or work on this equipment unless 

you have read and understand the instructions 

and warnings in the Operation and Maintenance 

Manuals. Failure to follow the instructions or heed 

the warnings could result in serious injury or 

death.

 

 

 

 

Electrical Shock

 

The safety message for electrical shock is located on the control panel.

 

 

WARNING! Shock/Electrocution Hazard! Read 

and understand the instructions and warnings in 

the Operation and Maintenance Manual. Failure to 

follow the instructions or heed the warnings 

could cause serious injury or death.

 

 

 

 

Additional Messages

 

 

There are several warning labels on this unit. Please be aware of all warning labels.

 

 

Make sure that all of the messages are legible. Clean the messages or replace the messages if the words or images are 

unreadable. When you clean the messages, use a cloth, water and soap. Do not use solvent, gasoline, or other harsh 

chemicals to clean the messages. Solvents, gasoline, or harsh chemicals could loosen the adhesive that secures the 

messages. Loose adhesive will allow the messages to fall off.

 

 

Replace any message that is damaged, or missing. If a message is attached to a part that is replaced, install a message on 

the replacement part. 

 

General Hazard Information 

Attach a 

“Do

 Not 

Operate”

 warning tag to the start switch or controls before the

 

unit is serviced or repaired. Attach the warning tags to the unit and to the operator 

control station. When appropriate, disconnect the starting controls. Do not allow 

unauthorized personnel on the unit, or around the unit when the unit is being 

serviced. Cautiously remove the following parts. To help prevent spraying or 

splashing of pressurized fluids, hold a rag over the part that is being removed.

 

 

Gage ports 

 Breathers

 

 Drain plugs

 

 

Use caution when cover plates are removed. Gradually loosen, but do not remove 

the last two bolts or nuts that are located at opposite ends of the cover plate or the 

device. Before removing the last two bolts or nuts, pry the cover loose in order to 

relieve any spring pressure or other pressure. 

 

Wear a hard hat, protective glasses, and other protective equipment, as required. 

Do not wear loose clothing or jewelry that can snag on parts of the unit. 

Ensure that all protective guards and all covers are secured in place on the unit. 

Never put maintenance fluids into glass containers. Glass containers can break. 

Use all cleaning solutions with care.  

Report all necessary repairs. 

 

 

 

Содержание AH150TON

Страница 1: ...150 TON AHU OPERATING AND SERVICE MANUAL STARTING S N AHU 150 22 00037 REV ...

Страница 2: ...ONTENTS Page No Description 1 Table of Contents 2 Safety Information 5 Technical Data Specifications 6 Operator Control Panel 7 Operation and Service 7 Troubleshooting 8 Electrical Schematic 9 Electrical Panel Layout 10 Structural Sheet Metal ...

Страница 3: ...that may cause product damage are identified in this publication TCRS cannot anticipate every possible circumstance that might involve a potential hazard The warnings in this publication and on the product are therefore not all inclusive You must not use this product in any manner different from that considered by this manual without first satisfying yourself that you have considered all safety ru...

Страница 4: ...that is damaged or missing If a message is attached to a part that is replaced install a message on the replacement part General Hazard Information Attach a Do Not Operate warning tag to the start switch or controls before the unit is serviced or repaired Attach the warning tags to the unit and to the operator control station When appropriate disconnect the starting controls Do not allow unauthori...

Страница 5: ...and components When using air for cleaning allow the machine to cool to reduce the possibility of fine debris igniting when redeposited on hot surfaces Fluid Penetration Always use a board or cardboard when you check for a leak Leaking fluid that is under pressure can penetrate body tissue Fluid penetration can cause serious injury and possible death A pinhole leak can cause severe injury If fluid...

Страница 6: ...pt Rating 10KAIC Minimum Circuit Ampacity 40 AMPS Enclosure Type Type 3R Control 110V Control 12V DC Blower Motor WATTS 4400 WATTS x4 FLA 6 6 AMPS x4 Circuit Protection 10 AMPS Condensate Pump H P 1 150 HP FLA 1 AMP Circuit Protection 2 AMPS Control Transformer Rating 500 VA Primary Fuse ATDR4 Secondary Fuse ATDR4 DBA 20 76 DBA DBA 20 with Ducts 66 DBA Weight 3500 LBS Made in USA ...

Страница 7: ...Contact TCRS at 440 658 2020 Operator Control Panel 6 ...

Страница 8: ...hooting Caution must be taken when troubleshooting the electrical circuit and should only be performed by a trained service technician INDICATION POSSIBLE CAUSE CORRECTIVE ACTION Nothing operates Main power Control power Check voltage Check transformer and fusing Blower Fault Breaker tripped Motor failure Find cause reset breaker Verify 480V 3ph is present Verify 0 10VDC control voltage is present...

Страница 9: ...Contact TCRS at 440 658 2020 8 Electrical Schematic ...

Страница 10: ...Contact TCRS at 440 658 2020 Electrical Panel Layout 9 ...

Страница 11: ...Contact TCRS at 440 658 2020 10 ...

Страница 12: ... Contact TCRS at 440 658 2020 11 ...

Страница 13: ... Contact TCRS at 440 658 2020 12 ...

Отзывы: