background image

Contact TCRS at 440-658-2020

 

Important Safety Information

 

 

Most accidents that involve product operation, maintenance and repair are caused by failure to observe 

basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous 

situations before an accident occurs. A person must be alert to potential hazards, including human factors 

that can affect safety. This person should also have the necessary training, skills and tools to perform these 

functions properly.

 

 

Improper operation, lubrication, maintenance or repair of this product can be dangerous and could 

result in injury or death.

 

 

Do not operate or perform any lubrication, maintenance or repair on this product, until you verify 

that you are authorized to perform this work, and have read and understood the operation, 

lubrication, maintenance, and repair information.

 

 

Safety precautions and warnings are provided in this manual and on the product. If these hazard warnings 

are not heeded, bodily injury or death could occur to you or to other persons.

 

 

The hazards are identified by the 

“Safety

 Alert 

Symbol”

 and followed by a 

“Signal

 

Word”

 such as 

“DANGER”, “WARNING” or “CAUTION”.

 The Safety 

Alert “WARNING” label is shown below.

 

 
 

The meaning of this safety alert symbol is as follows:

 

 

Attention! Become Alert! Your Safety is involved.

 

 

The message that appears under the warning explains the hazard and can be either written or pictorially 

presented.

 

 

A non-exhaustive list of operations that may cause product damage are identified in this publication.

 

 

TCRS cannot anticipate every possible circumstance that might involve a potential hazard.

 

The warnings in this publication and on the product are, therefore, not all inclusive. You must not 

use this product in any manner different from that considered by this manual without first satisfying 

yourself that you have considered all safety rules and precautions applicable to the operation of the 

product in the location of use, including site-specific rules and precautions applicable to the 

worksite. If a tool, procedure, work method or operating technique that is not specifically 

recommended by  TCRS is used, you must satisfy yourself that it is safe for you and for others. You 

should also ensure that you are authorized to perform this work, and that the product will not be 

damaged or become unsafe by the operation, lubrication, maintenance or repair procedures that 

you intend to use.

 

 

The information, specifications, and illustrations in this publication are on the basis of information that was 

available at the time that the publication was written. The specifications, torques, pressures, 

measurements, adjustments, illustrations, and other items can change at any time. These changes can 

affect the service that is given to the product. Obtain the complete and most current information before you 

start any job.

 

 
 

When replacement parts are required for this 

product, TCRS recommends using parts with 

equivalent specifications including, but not limited 

to, physical dimensions, type, strength and material.

 

 

Failure to heed this warning can lead to premature 

failures, product damage, personal injury or death.

 

 

Содержание AH150TON

Страница 1: ...150 TON AHU OPERATING AND SERVICE MANUAL STARTING S N AHU 150 22 00037 REV ...

Страница 2: ...ONTENTS Page No Description 1 Table of Contents 2 Safety Information 5 Technical Data Specifications 6 Operator Control Panel 7 Operation and Service 7 Troubleshooting 8 Electrical Schematic 9 Electrical Panel Layout 10 Structural Sheet Metal ...

Страница 3: ...that may cause product damage are identified in this publication TCRS cannot anticipate every possible circumstance that might involve a potential hazard The warnings in this publication and on the product are therefore not all inclusive You must not use this product in any manner different from that considered by this manual without first satisfying yourself that you have considered all safety ru...

Страница 4: ...that is damaged or missing If a message is attached to a part that is replaced install a message on the replacement part General Hazard Information Attach a Do Not Operate warning tag to the start switch or controls before the unit is serviced or repaired Attach the warning tags to the unit and to the operator control station When appropriate disconnect the starting controls Do not allow unauthori...

Страница 5: ...and components When using air for cleaning allow the machine to cool to reduce the possibility of fine debris igniting when redeposited on hot surfaces Fluid Penetration Always use a board or cardboard when you check for a leak Leaking fluid that is under pressure can penetrate body tissue Fluid penetration can cause serious injury and possible death A pinhole leak can cause severe injury If fluid...

Страница 6: ...pt Rating 10KAIC Minimum Circuit Ampacity 40 AMPS Enclosure Type Type 3R Control 110V Control 12V DC Blower Motor WATTS 4400 WATTS x4 FLA 6 6 AMPS x4 Circuit Protection 10 AMPS Condensate Pump H P 1 150 HP FLA 1 AMP Circuit Protection 2 AMPS Control Transformer Rating 500 VA Primary Fuse ATDR4 Secondary Fuse ATDR4 DBA 20 76 DBA DBA 20 with Ducts 66 DBA Weight 3500 LBS Made in USA ...

Страница 7: ...Contact TCRS at 440 658 2020 Operator Control Panel 6 ...

Страница 8: ...hooting Caution must be taken when troubleshooting the electrical circuit and should only be performed by a trained service technician INDICATION POSSIBLE CAUSE CORRECTIVE ACTION Nothing operates Main power Control power Check voltage Check transformer and fusing Blower Fault Breaker tripped Motor failure Find cause reset breaker Verify 480V 3ph is present Verify 0 10VDC control voltage is present...

Страница 9: ...Contact TCRS at 440 658 2020 8 Electrical Schematic ...

Страница 10: ...Contact TCRS at 440 658 2020 Electrical Panel Layout 9 ...

Страница 11: ...Contact TCRS at 440 658 2020 10 ...

Страница 12: ... Contact TCRS at 440 658 2020 11 ...

Страница 13: ... Contact TCRS at 440 658 2020 12 ...

Отзывы: