Factory Test & Alignment Specification For RT95-AP Series (V1.0)
13
SPDIF
DOSS
Audio output
PCMCIA
TV source
Suitbale PCMCIA Card
4.4 LAN/WLAN Test
MAC Address Upgrade
Upgrading MAC address needs to use the tool in factory and through serial command. The specific
method is according to the operation of the factory guidance.
DeviceID (DID) and UserID (UID)
Purpose is to allow Other Network Download (OND) and further specific services over dedicated portal
based on AP.For such, specific DID (32 bytes) and UID (8 bytes) needs to be paired and overwritten into
memory for internal client encryption,as below:
Device ID
User ID
8cecb4ee42adc69ec7d714160b03371db5df4fef
408BF6FAB8EC
Those DID/UID codes can only be set using UART commands following enclosed SIACP requirements
(rev. v3.9).
LAN Test
A rough LAN test can be done by connecting Ethernet to TV’s RJ45 and check that IP, subnet mask, DNS
addresses, which are visible on “
Home
Settings
Network Setting
Wired settings
Auto Get IP
Address
” (ensure that “Internet Connection” is Enabled at first). More in-depth test can be performed
faster using suitable UART/IR commands following SIACP requirements. SW will internally manage
Network ID (NID) flag controlling all MAC/DID/UID integrity to facilitate PA screening further.
See Appendix 3 “Network Connection”
4.5 SHOP INIT
At final process stage, it’s necessary to perform
Shop
init before any packing to leave Factory mode and
restore User default presets according to the requirement of order.
This function is accessible by selecting “
Factory Menu
Shop
”, then pressing RCU “
Right
”or”
Left
” key.
Other faster methods are available on above enclosed SIACP requirements (rev. v3.9).