T61 Smart Modem
Page 20 of 47
User Guide V1.4
7
Device Configuration
T61 Smart Modem is robust and comprehensive. Most of its properties are configurable to cater
different requirements. In this chapter, all configuration options will be discussed.
There are two ways to configure T61 Smart Modem. One way is using TMAS Center Manager
software (Refer to the Center Manager User Guide). The other way is to use serial terminal software.
And terminal software will do the job, while HyperTerminal and Hercules are recommended. A
configuration menu is embedded inside T61 smart gateway. User can easily configure the device via
serial port. In this chapter, we will focus on the serial port configuration method. All screenshots are
taken using HyperTerminal.
7.1
Initial Setup
To configure T61 smart gateway, serial terminal software should be configured as followed:
Baud Rate: 115200bps
Data Bits: 8
Parity Bit: None
Flow Control: None
The factory default operation mode of T61 smart gateway is Normal Modem Mode, switch to Smart
Modem Mode before you continue. After powering up the device, you will see the start-up menu
shown in Figure 8. This start-up menu includes device mode, firmware version and product serial
number.
Figure 8: Start-up Menu