Chapter 2 Installation
System Configuration
2-5
TC8612 Rev 1.1 User Manual
•
INT CLK:
Internal Clock. This switch (SW3) is used to setup the internal
clock. "On" for internal T1/E1 timing mode. "Off " for Rx loop timing.
•
B8ZS / HDB3:
This switch (SW4) is used to setup the T1/E1 Line Code. "On"
for B8ZS (T1) / HDB3 (E1). "Off" for AMI (Both T1/E1).
•
DIS ALM:
This switch (SW5) is used to disable alarm outputs.
•
L1, L2, L3:
These switches (SW6, SW7, & SW8) are used to set the DSX-1
cross-connect distance (copper line build-out) for T1 applications or the
impedance for an E1 application.
For example, in a T1/E1 application, this is the length of twisted pair cable
connecting the TC8612 to the user's equipment, which may be a CSU or DSU. See
Table 2-1 and Table 2-2.
Table 2-1: Copper Line Length Setup Table
Table 2-2: E1 Termination Setup Table
T1 Settings
L1
L2
L3
Application Line Length
Up
Up
Up
DSX-1 (0 to 133 feet) / 0 dB CSU
Down
Up
Up
DSX-1 (133 to 266 feet)
Up
Down
Up
DSX-1 (266 to 400 feet)
Down
Down
Up
DSX-1 (400 to 533 feet)
Up
Up
Down
DSX-1 (533 to 655 feet)
Down
Up
Down
-7.5 dB CSU
Up
Down
Down
-15 dB CSU
Down
Down
Down
-22.5 dB CSU
E1 Settings
L1
L2
L3
Application Termination
Up
Up
Up
75 Ohm Normal
Down
Up
Up
120 Ohm Normal
Up
Up
Down
75 Ohm High Loss
Down
Up
Down
120 Ohm High Loss