TBS Installation Manual
–
3D FLASH+
TBS 3D FLASH+ Mounting and Installation Guideline
•
TBS-061
•
Rev 11-2023
page 14 of 17
5
Appendix
5.1
Maintenance
Cleaning
Prior to disinfection the devices should be cleaned to remove dust or dirt.
Use warm water with a few drops of soap or a combined cleaning & disinfection liquid normally used to
wash hands. Don’t use aggressive detergents.
Use soft towels for cleaning only, don’t use abrasive cleaning equipment.
Pay attention never to use aggressive chemical cleaning agents, as these could attack the plastic housing
of the device.
Disinfection
TBS devices can be disinfected with antiseptic liquid, e.g. Sagrotan, Dettol or a similar disinfectant
applied as a spray.
Function check
TBS terminals are designed for permanent usage. Therefore, problems in the operation of the devices
are detected during regular usage. Special tests to check for correct functioning are therefore not
required.
TBS recommends checking the integrity of the terminals at least every 6 months. If the devices are used
in environments with dust or where oily substances are handled or other extraordinary environmental
factors are present, the sensor surfaces need to be checked and cleaned with increased frequency.
Replacement Parts
When used in normal operation, no maintenance parts should be needed for 3D FLASH+.
5.2
Trouble Shooting
The following table provides brief description of device error codes and quick resolutions.
Error code Description
Resolution
0
No error.
1
General error.
42
Sensor image caching (sensor returned
two same images in a row).
100
Unknown DB error.
101
DB empty.
Add users or reload database from BioManager.
102
Database limit reached.
103
DB corrupted.
Reload database from BioManager.
200
Unknown configuration error.
Verify the settings in DeviceConfig.
201
Wrong configuration set.
Verify the settings in DeviceConfig.
300
Unknown server communication error.
301
Device blocked (Off Active flag on
server).
Enable active flag on BioManager.
302
Device
blocked
remotely
using
RemoteControl interface.
303
Device not connected to server (either
wrong configuration or connection
problems).
304
Device not validated on server.
Validate the device on BioManager.
305
Device in non-operable state - DB reload
in progress.
Wait for DB reload process to complete.