User Manual of Solar Intelligent Energy System (SIES)
TBB Power Confidential Page
49
of
66
4) Inverter settings:
Rated voltage, PS mode
6.4 System Control
6.4.1 Silent mode
When a typical system failure happens, its fault code will be displayed in the information area of
Battery Status in Cyber. Cyber will keep beeping to remind checking and solving the fault.
To stop the beeping of system failure, Cyber can be set to enter
“Silent” mode, following the below
operation:
Slightly press the ”SILENT” button, when ”SILENT ON” is blinking at the top left corner of Cyber,
press the ” Enter” button, then Cyber will enter into the “Silent” mode.
6.4.2 Load Management
When the programmable AC output L2 or L3 was switched off as a result of that the preset conditions
had been triggered on, Cyber will show L2 OFF or L3 OFF in the information area of Energy
Consumption.
If L2 or L3 was switched off due to overload protection, you need to switch on the AC output after
the overload warning had disappeared. Follow the below instruction to manually switch on L2 or L3
again by Cyber.
For example, if L2 was switched OFF, firstly press
“FUNC” button till the L2 OFF is disappeared
from Cyber
, then press “ ENTER” Button, the icon of L2 will be switched ON again.
If L2 or L3 was switched off because of other reasons, L2 and L3 can be switched on automatically.
6.4.3 Battery Equalization
Over a period of time, the cells in a flooded or OPZS battery can develop uneven chemical states.
This will result in a weak cell which further reduces the overall capacity of battery. To improve the
lifespan and performance of these non-sealed batteries, Energier Pro bi-directional inverter provides
a manual equalization program (EQ) which can be put into operation as recommended by battery
manufacturer.