Built in BMS pre-defined LFP charging and communication.
According to cell temperature and real time SOC, BMS will send command to battery charger
asking for optimum charging voltage and current. This synchronization will prevent overheating or
overcharging especially at the end of charging, to ensure the lithium battery reaches its target
cycle life
In the meantime, instead of using voltage as protection, SOC value is used with more accuracy
thus to avoid permanently dead of lithium battery due to left discharged for long time.
2.3.4 Protect function
The Energier Mobile Inverter Charger Combination is equipped with a series of complete
hardware and software protection functions to ensure its stable and reliable operation.
Overload protection
When overload protection is trigger on, it will restart automatically after 60s. And after three
consecutive overload shutdown protections, the equipment will not restart automatically. At this
time, the user needs to manually restart.
Over temperature protection
When the internal temperature is too high, Energier Mobile will enter into the over-temperature
protection. After the internal temperature returns to normal, it can automatically resume normal
operation.
Short circuit protection
The equipment will automatically shut down when the AC output is shorted and needs to be
manually activated.
Battery over temperature protection
During the charging, the equipment will continuously monitor the battery temperature. When the
battery temperature is too high, the equipment will automatically reduce the charging current.
When the battery is severely heated, the charger will automatically turn off to protect the battery.
Battery low voltage protection
To prevent the permanent damage caused by the over discharge of battery, the equipment will
automatically cut off the output according to the low voltage protection point set by the user.
2.3.5 Communication
Dry contact input
Energier Mobile is equipped with a dry contact input for remote on/off, often IGN was connected.
RS485
Equipped with a RS485 interface.