background image

INSTALLATION INSTRUCTIONS

 

MANDALAY 06-4006HS

ROMAN TUB FAUCET

THIS FAUCET MEETS OR EXCEEDS THE FOLLOWING STANDARDS: 

ASME A112.18.1/CSA B125.1 and NSF-61

TURN OFF

TURN OFF

SI

LI

CO

NE

Your installation may require new supply 
lines. (Supply lines are not included.)

® REGISTERED TRADEMARK OF TAYMOR INDUSTRIES LTD.

CUSTOMER SERVICE      WEST 1-800-267-4774   |   EAST 1-800-387-7064   |   taymor.com

1

2

THANK YOU

 FOR PURCHASING THIS TAYMOR PRODUCT. ALL TAYMOR PRODUCTS ARE CAREFULLY

ENGINEERED AND FACTORY TESTED TO PROVIDE LONG TROUBLE-FREE USE UNDER NORMAL CONDITIONS.

HAVE BASIC TOOLS READY

RECOMMENDED TOOLS:

1

Flashlight

Teflon tape Screwdrivers

Adjustable

wrench and

pipe wrench

Plumber’s putty

Safety goggles

Torque wrench

Silicone caulk

2

TURN OFF THE MAIN WATER SUPPLY

Locate water supply inlets and shut off water supply valves. 

These are usually found near water meter.

WARNING: READ ALL

 the instructions completely before beginning.  

READ ALL

 warnings, care and maintenance information.

Taymor recommends calling a professional if you are uncertain about installing this product!

This product should be installed in accordance with all local and provincial plumbing and building codes.

Need Help?

 Please call our toll-free Customer Support line at 

(WEST) 1-800-267-4774     (EAST ) 1-800-387-7064 for additional assistance or service.

3

DECK PREPARATION

Drill holes in FINISHED DECK per diagram.

NOTE: This kit is intended for installation up to 1-1/4” thick.

4

INSTALL THE VALVE SYSTEM

Place a flange on each housing assembly. 

Thread each flange down. Adjust each lower 

locknut and washer. Wrench tighten locknuts.

5

HANDLE INSTALLATION

Install handles (1), secure with screw (2), insert cap (3) and tighten the set screw (4).

Remove lift rod knob (1) and remove set 

screw (2).

Remove spout (1) from diverter body (2).

Remove connector (1) from diverter body (2).

From underneath the deck, insert diverter 

body with rubber washer (1), metal washer 

(2) and mounting nut (3) through center hole. 

From above, thread connector (4) onto di-

verter body. Tighten mounting nut (3), so that 

the connector (4) sits flush to the surface of 

working area.

TORQUE

11 - 15 FT/LBS.

7

SPOUT INSTALLATION

Assemble and align spout (1) onto diverter body and tighten set screw (2). Insert index 

(5). Place lift rod knob (3) onto lift rod (4) and hand tighten.

Remove flange (1) from housing assembly.

With the housing assembly marked “HOT” on 

the left, insert the housing assembly through 

the mounting holes from the underside of the 

deck/rim.

A

B

C

6

DIVERTER INSTALLATION

A

B

C

D

1

1

TORQUE

11 - 15 FT/LBS.

TORQUE

11 - 15 FT/LBS.

2

1

3

2

1

4

1

2

4

2

1

3

2

1

3

4

5

4~6"

(10.

2-15

.2cm

)

5" m

in.(1

2.7cm)

3" 

min

.

      

      

     

     

      (

7.6c

m)

8~16

"(20.3

-40.6c

m)

Ø1-3/8”

(35mm)

Ø1-1/8”

(29mm)

Ø1-3/8”

(35mm)

Ø1-3/8”

(35mm)

1-1/8

” (29m

m) M

AX. D

ECK

 THIC

KNE

SS

Отзывы: