OPERATING PROCEDURES
6-13
Models C709 & C717
Operating Procedures
6
3.
Open the draw valve on the freezer door. Drain all the
rinse water from the door spout. Close the draw
valve, and press the Wash key,
/
canceling the Wash mode.
4.
Repeat this procedure using clean, warm water, until
the water being discharged is clear.
5.
Repeat steps 1 through 4
for the other side of the
C717.
Hopper Cleaning
1.
Prepare a 2-1/2 gal. (9.5 L) pail of a Taylor-approved
cleaning/sanitizing solution with an active chlorine
concentrate of 100 PPM to 200 PPM.
Important!
Use warm water and follow the cleaning/
sanitizing solution manufacturer's specifications.
2.
Pour the solution into the hopper and allow it to flow
into the freezing cylinder.
3.
Using the white hopper brush, clean the mix hopper,
mix-level sensing probes, and the outside of the
agitator driveshaft housing. Using the double-ended
brush, clean the mix inlet hole.
Note:
Do not brush-clean the mix inlet hole while
the machine is in the Wash mode.
4.
Press the Wash key
/
. The cleaning
solution in the freezing cylinder will contact all areas
of the freezing cylinder.
5.
Place an empty pail beneath the door spout(s).
6.
Open the draw valve on the freezer door and draw off
all the solution.
7.
Once the cleaning solution stops flowing from the
door spout, close the draw valve and press the
Wash key
/
, canceling the Wash mode.
8.
Repeat steps 1 through 7
for the other side of the
C717.
Disassembly
Note:
Failure to remove the parts specified below for
brush-cleaning and lubrication will result in damage to
the machine. These parts must be removed within the
maximum number of days allowed between brush-clean
cycles, or the machine will hard lock and will not operate.
WARNING!
Make sure the power switch is in
the OFF position! Failure to follow this instruction may
result in severe personal injury to fingers or hands from
hazardous moving parts.
1. Remove the handscrews, freezer door, beater,
scraper blades, and driveshaft with driveshaft seal
from the freezing cylinder.
2. Remove the scraper blades.
3. Remove the driveshaft seal from the driveshaft.
4. Remove the freezer door gasket(s), front bearing(s),
pivot pin(s), draw handle(s), and draw valve(s).
Remove the three O-rings from the draw valve(s).
5.
Model C717:
Remove the design caps.
6. Remove the front drip tray and splash shield.
7. Remove all drip pans and take them to the sink for
cleaning.
Figure 6-45
Note:
If the drip pans are filled with an excessive
amount of mix, the driveshaft seal(s) or O-ring(s)
should be replaced or properly lubricated.
8.
Repeat steps 1 through 7
for the other side of the
C717.
10176
Содержание C709
Страница 8: ...1 4 TO THE INSTALLER Models C709 C717 To the Installer 1 Notes...
Страница 22: ...4 10 OPERATOR PARTS IDENTIFICATION Models C709 C717 Operator Parts Identification 4 Notes...
Страница 58: ...8 4 TROUBLESHOOTING GUIDE Models C709 C717 Troubleshooting Guide 8 Notes...
Страница 60: ...9 2 PARTS REPLACEMENT SCHEDULE Models C709 C717 Parts Replacement Schedule 9 Notes...
Страница 64: ...10 4 LIMITED WARRANTY ON EQUIPMENT Models C709 C717 Limited Warranty on Equipment 10 Notes...
Страница 68: ...11 4 LIMITED WARRANTY ON PARTS Models C709 C717 Limited Warranty on Parts 11 Notes...