OPERATING PROCEDURES
6-7
Model C612
Operating Procedures
6
17. Slide the two shorter drip pans into the holes in the
rear panel. Slide the two drip pans with holes into the
left and right side panels. (See Figure 6-27.)
Figure 6-27
18. Install the front drip tray and splash shield under the
door spouts. (See Figure 6-28.)
Figure 6-28
Mix Pump Assembly
1. Inspect the rubber and plastic pump parts. The
O-rings, check rings, and gaskets must be in good
condition for the pump and entire machine to operate
properly. They cannot properly serve their intended
function if nicks, cuts, or holes in the material are
present.
Inspect the plastic pump parts for cracks, wear, and
delamination of plastic.
Replace and discard any damaged parts
immediately.
2. Assemble the piston. Slide the red O-ring into the
groove of the piston.
Do not
lubricate the O-ring.
(See Figure 6-29.)
Figure 6-29
3. Apply a thin layer of lubricant to the inside of the
pump cylinder at the retaining pin end.
(See Figure 6-30.)
Figure 6-30
4. Insert the piston into the retaining pin end of the
pump cylinder. (See Figure 6-31.)
Figure 6-31
Содержание C612
Страница 8: ...1 4 TO THE INSTALLER Model C612 To the Installer 1 Notes...
Страница 54: ...9 2 PARTS REPLACEMENT SCHEDULE Model C612 Parts Replacement Schedule 9 Notes...
Страница 58: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C612 Limited Warranty on Equipment 10 Notes...
Страница 62: ...11 4 LIMITED WARRANTY ON PARTS Model C612 Limited Warranty on Parts 11 Notes...