1.
Open the lighted display door. Place the control
switch in the ON position.
Figure 6-22
2.
Prepare a pail of approved 100 PPM sanitizing
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or 2
gal. [7.6 L] of Stera-Sheen
®
). Use warm water and
follow the manufacturer's specifications.
Important! Make sure the sanitizer is completely
dissolved.
3.
Using an empty bag of syrup, cut the syrup line
connector from the end of the bag.
Figure 6-23
4. Connect the syrup line to the syrup line connector
that was cut from the syrup bag.
Figure 6-24
5. With the bag connector attached to the syrup line,
place the syrup line into the pail of sanitizing solution.
Figure 6-25
6. To place the left freezing cylinder in the Sanitize
mode, press the menu (SEL) key. Move the cursor by
pressing the AUTO (- ->) key until the third line
indicates RINSE / SANITIZE.
13092
17011
17041
17013
OPERATOR MENU
A B C D E F G H I
RINSE / SANITIZE
L
E
S
>
-
-
-
-
<
Содержание C302NP