TO THE INSTALLER
1-3
Model C302
To the Installer
1
Electrical Connections
Each freezer requires one power supply. Check the data
label on the freezer for branch circuit over current
protection or fuse, circuit amp capacity, and electrical
specifications. See the wiring diagram provided inside of
the control box for proper power connections.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical Code
(NEC), ANSI/NFPA 70-1987. In all other areas of the
world, equipment should be installed in accordance with
the existing local codes. Please contact your local
authorities.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety. Compliance
therewith and proper maintenance will result in an
installation essentially free from hazard.
The NEC is a United States regulatory agency.
International users must follow local electrical codes.
WARNING!
This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
IMPORTANT!
An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug to be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
•
Stationary machines which are not equipped
with a power cord and a plug or another device
to disconnect the machine from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in.
(3 mm) installed in the external installation.
•
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to the
local codes.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be replaced by an
authorized Taylor service technician in order to avoid a
hazard.
Beater Rotation
NOTICE!
Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at the
machine main terminal block only. To correct rotation on
a single-phase machine, exchange leads inside the
beater motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.
It is recommended that beater rotation adjustment be
performed by an authorized Taylor service technician.
!
FOLLOW YOUR LOCAL ELECTRICAL CODES.
Содержание C302
Страница 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Страница 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Страница 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...