5-4
USER INTERFACE
Model C302
User Interface
5
7. CO
2
PRESSURE LOW—When the CO
2
out indicator
displays a lack of CO
2
, a 60-second internal timer will
start. If the CO
2
is not replenished at the end of the
60 seconds, both freezing cylinders will shut down
and this fault message will appear. Replenish the
CO
2
, and the fault message and warning tone will
clear.
8. H
2
O PRESSURE LOW—When the water out
indicator displays a lack of water, a 60-second
internal timer will start. If the water is not replenished
at the end of the 60 seconds, all freezing cylinders
will shut down and this fault message will appear.
Replenish the water, and the fault message and
warning tone will clear.
9. BRL NOT COOLING—A freezing cylinder check has
been established for the Auto mode of operation. If a
freezing cylinder enters the Auto mode, the control
will check product temperature. After 5 minutes, it will
again check product temperature. If product
temperature does not drop in that 5-minute time
span, the freezing cylinder will shut down and this
message will appear on the fault screen. For this
check to be valid, the product temperature must be
above 40°F (4.4°C).
10. BRL TEMP 2 HIGH—A maximum allowable product
temperature has been established to prevent product
from excessive heating. If the product exceeds
120
°
F (49
°
C) for any reason (in any mode of
operation), the entire machine shuts down.
Faults, when corrected, are cleared from the Fault
Description screen, with the following exception: BRL
NOT COOLING. This fault requires the operator to
press the OFF (<- -) key (when in the fault description
screen) in order for the fault to discontinue.
To see if there is more than one fault in either
freezing cylinder, press the PRIME (+ + +) key. To
return to the operator menu, press the MENU
(SELECT) key once. To return to the main screen,
use the AUTO (- ->) key to cycle to menu item A, then
press the MENU (SELECT) key.
11. Screen C is SET CLOCK. Use the AUTO (- ->) and
OFF (<- -) keys to place the cursor under the element
to be set (hours, minutes, month, day, or year). Use
the PRIME (+++) and BEATER (- - -) keys to increase
or decrease the value. Press the MENU (SELECT)
key to advance to the Daylight Saving Time screen.
Note:
The clock is programmed with military time.
This screen will appear if an invalid date is entered
(example: if the date entered exceeds the days of
that month).
FAULT DESCRIPTION
L: CO2 PRESSURE LOW
R: CO2 PRESSURE LOW
CLR
+ + +
SEL
FAULT DESCRIPTION
L: H2O PRESSURE LOW
R: H2O PRESSURE LOW
CLR
+ + +
SEL
FAULT DESCRIPTION
L: BARREL NOT COOLING
R: NO FAULT FOUND
CLR
+ + +
SEL
FAULT DESCRIPTION
L: BARREL TEMP 2 HIGH
R: NO FAULT FOUND
CLR
+ + +
SEL
SET CLOCK
14:30
2/25/04
<- - - -> + + +
- - -
SEL
SET CLOCK
14:30
02/31/04
INVALID DATE
SEL
Содержание C302
Страница 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Страница 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Страница 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...