USER INTERFACE
5-3
Model C302
User Interface
5
Table 5-1
The following are explanations of the possible faults and
the display screens. Lines 2 and 3 indicate the faults
found in freezing cylinders 1 and 2 respectively.
1. NO FAULT FOUND—No fault conditions are
apparent.
2. BEATER OVERLOAD—Beater motor is out on
overload. When this fault occurs, the affected side of
the machine automatically turns off. The fault clears
when the condition is corrected.
3. CHK REFRIG SYS PSI—Compressor is out on high
head pressure. When this fault occurs, the machine
automatically turns off. The fault clears when the
condition is corrected.
4. THERMISTOR SHORT—One or both of the barrel
(freezing cylinder) thermistor probes are faulty.
5. THERMISTOR OPEN—One or both of the barrel
(freezing cylinder) thermistor probes are faulty.
6. SYRUP PRESS LOW—When the syrup out indicator
displays a lack of syrup, the barrel will enter a Hold
mode. At this time, no refrigeration or product flow
from the flow control will be allowed. Only the beater
will operate. When the syrup is satisfied the barrel
will refill the product tank and then automatically
return to the Auto mode. The fault message and the
warning tone will clear. (See Syrup Out Indicator on
page 5-7.)
Fault Messages
Beater Overload
Beater is out on overload.
Chk Refrig Sys Psi
Out on compressor high
pressure cut-out.
Thermistor Short
Shorted thermistor probe.
Thermistor Open
Open thermistor probe.
H
2
O Pressure Low
Water pressure is low.
CO
2
Pressure Low
CO
2
pressure is low.
Syrup Pressure Low
Syrup is no longer present.
BRL Temp 2 High
Freezing cylinder temperature
is above 120°F (49°C).
BRL Not Cooling
Freezing cylinder is not
cooling after 5 minutes.
No Fault Found
No fault conditions are
apparent.
FAULT DESCRIPTION
L:
NO FAULT FOUND
R:
NO FAULT FOUND
CLR
+ + +
SEL
FAULT DESCRIPTION
L: BEATER OVERLOAD
R: BEATER OVERLOAD
CLR
+ + +
SEL
FAULT DESCRIPTION
L: CHK REFRIG SYS PSI
R: CHK REFRIG SYS PSI
CLR
+ + +
SEL
FAULT DESCRIPTION
L: THERMISTOR SHORT
R: NO FAULT FOUND
CLR
+ + +
SEL
FAULT DESCRIPTION
L: THERMISTOR OPEN
R: NO FAULT FOUND
CLR
+ + +
SEL
FAULT DESCRIPTION
L: NO FAULT FOUND
R: SYRUP PRESS LOW
CLR
+ + +
SEL
Содержание C302
Страница 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Страница 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Страница 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...