5-2
USER INTERFACE
Model C302
User Interface
5
cylinders located directly beneath them. These pairs of
freezing cylinders are each labeled left and right per
LCD.
The LCDs show the current operating mode of the
freezing cylinders. They also indicate whether there is
enough syrup, CO
2
, and water being supplied to the
freezer. If an error in the machine operation occurs, a
warning tone will sound and the word FAULT will flash on
the third line of the display.
Operational Mode Displays
The screens below illustrate the operational mode
information displayed during normal operation. The two
LCDs display information corresponding to the two
freezing cylinders located directly beneath them. These
pairs of freezing cylinders are each labeled left and right
per LCD.
When the machine is plugged into the wall receptacle
and the control switch is in the ON position, this screen
appears.
This display will remain on the LCD for 60 seconds
unless a key is pressed. If any key is pressed
(or 60 seconds pass), the next screen appears.
Note:
Syrup, CO
2
and water are satisfied.
Pressing the AUTO (- ->) keys for each freezing
cylinder will display this screen.
Line 1 indicates the operating mode for each freezing
cylinder.
Line 2 indicates the status of the syrup systems in each
freezing cylinder. As long as syrup is available, the word
OK will appear on the LCD. When the syrup supply is
insufficient, the word OUT will flash on the LCD. The
same rules apply to the fourth line, which indicates the
status of the CO
2
and the H
2
O.
The third line of this display is a fault indicator. If an error
in machine operation occurs, the word FAULT will be
displayed on the LCD.
Note:
Repeat all information and programming
procedures for each individual control from the left to the
right.
Operator Menu Display
The operator menu is used to enter into the operating
screens. To access the operator menu, simply press the
MENU (SELECT) key. The cursor will flash under the
letter A, indicating that this is screen A. To select a
different screen, use the AUTO (- ->) and OFF (<- -) keys
to move the cursor to the desired screen selection and
press the MENU (SELECT) key.
Operator Menu Timeout
If the display is left in the operator menu or any of the
operator menu selections, except for Current Conditions,
the display will return to the system mode screen 60
seconds after the last keypress. The Current Conditions
screen will be displayed until manually changed.
Finding Current Fault Conditions
Screen B is FAULT DESCRIPTION. The fault description
will indicate if there is a fault in one of the freezing
cylinders. When the actual fault is corrected, the warning
tone will stop. Only BRL NOT COOLING requires
pressing the OFF (<- -) key to clear the fault message
and the warning tone.
SAFETY TIMEOUT
ANY KEY ABORT
OFF
MODE
OFF
OK
SYRUP
OK
CO2-OK
WATER-OK
AUTO
MODE
AUTO
OK
SYRUP
OK
CO2-OK
WATER-OK
BEATER
MODE
BEATER
OUT
SYRUP
OUT
- -FAULT- -
- -FAULT- -
CO2-OUT
H2O-OUT
OPERATOR MENU
A B C D E F G H I
EXIT MENU
L
E
S
>
-
-
-
-
<
Содержание C302
Страница 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Страница 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Страница 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Страница 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Страница 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Страница 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...