5-2
USER INTERFACE
Models 8752, 8756, and 8757
User Interface
5
Symbol Definitions
To better communicate in the international arena, the
words on many of our operator switches and buttons
have symbols to indicate their functions. Your Taylor
machine is designed with these international symbols.
Figure 5-2
Power Switch
When placed in the ON position, the power switch allows
Softech™ control panel operation.
RESET Button
The RESET button is located in the decorative plate
above the Softech™ controls. The reset protects the
beater motor from an overload condition. If an overload
occurs, the reset mechanism will trip. To properly reset
the machine, press the AUTO button to cancel the cycle.
Turn the power switch to the OFF position. Press the
RESET button firmly. Turn the power switch to the ON
position.
Press the WASH button and observe the machine’s
performance. Open the side access panel to check if the
beater motor is turning the driveshaft in a clockwise (from
operator end) direction without binding.
If it is turning properly, press the WASH button to cancel
the cycle. Press the AUTO button to resume normal
operation. (On models 8756 and 8757, press the AUTO
button on both sides to resume normal operation.) If the
machine shuts down again, contact a service technician.
Indicator Lights
MIX LOW
When the MIX LOW light begins to flash, the mix tank
has a low supply of mix and should be refilled as soon as
possible.
MIX OUT
When the MIX OUT light begins to flash, the mix tank has
an insufficient supply of mix to operate the machine. At
this time, the standby and Auto mode is locked out and
the machine shuts down. To initiate the refrigeration
system, add mix to the tank and press the AUTO button.
The machine will automatically begin operation.
Softech™ Control Operation
MIX REF
When the MIX REF button is pressed, the mode indicator
lights indicate that the mix cabinet refrigeration system is
operating. (On Models 8756 and 8757, there are two
touch-tone panels, one for each freezing cylinder. The
mix refrigeration system is controlled by the MIX REF
button found on the left panel. If the AUTO button is
pressed on either side of the machine, the MIX REF
function is automatically activated.) The MIX REF
function cannot be canceled unless the Auto or Standby
mode is canceled first.
Item
Description
1
Power Switch (Toggle)
2
RESET Switch
3
Mix Refrigeration Control
4
STANDBY Button
5 WASH
Button
6
AUTO Button
7
PUMP Button
8
MIX LOW Indicator
9
MIX OUT Indicator
10
Heater Switch
= AUTO
= ON
= OFF
= MIX REF
= WASH
= PUMP
= STANDBY
= MIX LOW
= MIX OUT
= HEATER ON
Содержание 8757
Страница 14: ...3 4 SAFETY Models 8752 8756 and 8757 Safety 3 Notes...
Страница 24: ...4 10 OPERATOR PARTS IDENTIFICATION Models 8752 8756 and 8757 Operator Parts Identification 4 Notes...
Страница 28: ...5 4 USER INTERFACE Models 8752 8756 and 8757 User Interface 5 Notes...
Страница 52: ...9 2 PARTS REPLACEMENT SCHEDULE Models 8752 8756 and 8757 Parts Replacement Schedule 9 Notes...
Страница 58: ...11 4 LIMITED WARRANTY ON PARTS 8752 8756 and 8757 Limited Warranty on Parts 11 Notes...