OPERATING PROCEDURES
6-5
Models 441 & 444
Operating Procedures
6
Figure 6-15
6. When the sanitizer stops flowing from the door spout,
lower the draw arm and place the control switch in
the OFF position.
Important! The unit must NOT be placed in AUTO
until all sanitizing solution has been removed from
the freezing cylinder and proper priming procedures
have been completed. Failure to follow this
instruction may result in damage to the freezing
cylinder.
IMPORTANT! If this machine is freshly
sanitized, make sure your hands are sanitized before
continuing these instructions. Failure to follow this
instruction may result in health hazard
s.
7. Stand the mix feed tube in the corner of the mix
hopper.
Figure 6-16
for the other side of the
freezer on the Model 444.
Priming
Prime the machine as closely to the time of first product
draw as possible.
1. Place a pail beneath the door spout and raise the
draw arm. Pour 2 gal (7.6 L) of
fresh
mix into the
hopper and allow it to flow down into the freezing
cylinder. This will force out any remaining sanitizing
solution.
Figure 6-17
2. When full strength mix is flowing from the door spout,
lower the draw arm.
Important! Failure to remove all sanitizing solution
may result in damage to the freezing cylinder.
3. When the mix has stopped bubbling down into the
freezing cylinder, install the mix feed tube into the mix
inlet hole.
Figure 6-18
10181
!
12050
12181