Page 23
Operator Manual
MB-280-02
Fault Codes
Note: Most faults are a result of a fault in the control system that will require service by a qualified
technician. These faults are shown here for reference only.
Operator correctable faults are shown in bold and underlined.
Level 1 Faults
Code
Description
What to do
F01000
P/S Motor Overheated
Stop the vehicle and allow the system to cool down.
F01001
Motor Brush Fault
Refer to service technician
F01002
Pump Motor Brush Fault
Refer to service technician
F01003
P/S motor Brush Fault
Refer to service technician
F01004
Low Battery Volts
Batteries are empty and require charging. If this fault does not reset
after the charge cycle is complete then there may be a problem with
the charger or batteries. Refer to qualified service technician.
F01005
Controller Overheated
Stop the vehicle and allow the system to cool. This could be a result of
an overloaded vehicle.
F01006
Traction Motor Hot
Stop the vehicle and allow the system to cool down. This could be a
result of an overloaded vehicle
F01007
Pump Motor Overheated
Stop the vehicle and allow the system to cool down.
F01008
Wiring fault
Refer to service technician
Level 2 Faults
Code
Description
What to do
F02000
Throttle Fault
Refer to service technician.
F02001
Throttle Fault
Refer to service technician.
F02002
Belly Switch Fault
Refer to service technician
F02003
Open Field
Refer to service technician
F02004
Open Field L
Refer to service technician
F02005
Open Field R
Refer to service technician
Level 4 Faults
Code
Description
What to do
F04000
Open Contactor
Refer to service technician
F04001
Contactor Welded
Refer to service technician
F04002
Steer POT Fault
N/A
F04003
Sequence Fault
Start up switches were not operated in the correct order. Refer to
Vehicle Operation Guidelines for correct sequence.
F04004
F&R Fault
Refer to service technician
F04005
F&R Fault
Direction was selected before start switch was closed. Place direction
selector in the OFF position and restart.
F04006
Interlock Fault
Seat or foot interlock switch not closed.
F04007
Inch Switch Fault
Direction Control switch NOT in neutral.
F04008
Steer Fault
Refer to service technician
F04009
Low Battery Volts
Extreme low battery voltage at the controller. May be a result of
severely discharged battery or wrong battery installed. Confirm
that the correct battery is installed and charge the battery.
F04010
High battery Volts
Refer to service technician
F04011
Out of Range Fault
Refer to service technician
F04012
CRC Fault
Refer to service technician
F04013
Capacitor Fault
Refer to service technician
Level 5 Faults
All Level 5 faults indicate a failure in the motor speed control system. Refer repair to a service technician.
Содержание BT-280 Series
Страница 55: ...Index 55...