•  The touch bolt can be  removed if it is in the way for normal lifting operations. Remove the bolt 

and plug the bolt hole with a standard M8 bolt and nut.

•  The touch bolt must be adjusted to the exact right position depending on the suction foot. Please 

contact your salesman to be sure of the position.

≈20mm

a

•  Make sure to use the correct torque for the bolts when installing the suction foot. Do not over- or 

undertighten. Air leakage may occur otherwise, reducing lifting capacity.

•  If the quick release attachment is used, the touch bolt must be removed.

≈10mm

b

The touch bolt provides help for the operator by 

opening the suction head valve fully, enabling a 

good grip of the load.
2.  Fit the touch bolt:

a.  Fit the touch bolt with the head of the bolt 

about 10-20 mm  below the edge of the suc-

tion foot (a).

b.  If the suction foot for sacks is used, adjust 

the bolt head so that it is installed approxi-

mately 10 mm above the edge of the suction 

foot (b).

3.  If the quick change attachment is used, install 

a suitable suction foot, see 

Change suction foot, 

quick release on page 17.

 

4.  Verify that the suction foot is securely fas-

tened to the suction head.

Содержание VacuEasylift

Страница 1: ...User guide for TAWI VacuEasylift...

Страница 2: ...chapter presents an overview illustration of the lifters and a table containing characteristics of the different models The VM60 model is used for all illustrations in this manual Your model may diffe...

Страница 3: ...operation dB 73 75 75 78 78 79 Model VM120 VM180 VM270 Lifting capacity kg 120 180 270 Lift tube mm 230 250 300 Stroke mm 1700 2400 1500 1500 Lift tube length mm 2500 4000 2500 2500 Noise level Idle d...

Страница 4: ...ember that a jib crane is more effective if the lifting equipment is more often used at the outer part of the jib arm c A a b 3 Connect the vacuum pump power supply c A motor circuit breaker with hold...

Страница 5: ...nected to a thermal relay for overheating protec tion e Wait at least 60 seconds and let the fan stop before turning it on again f 6 Verify function of the vacuum pump and that it rotates in the cloc...

Страница 6: ...plate to the vacuum pump outlet reducing socket with hose clamps use a torque of min 5 Nm c 6 Mount the silencing hood on the base plate Verify that the outlet is not blocked and that there is enough...

Страница 7: ...e between the filter unit and the lift tube top swivel with hose clamps use a clamp torque of 5 Nm c VM0 40 50 come with a reducing socket which is placed inside the filter inlet The fil ter inlet and...

Страница 8: ...5 2 cm of neoprene approxi mately 5 5 cm for models VM100 270 c 6 Push the top swivel into the lift tube d At least one complete spiral winding must cover the swivel 7 Make sure the area is clean and...

Страница 9: ...m measured from the top of the suction head 4 Make sure the area is clean and dust free before taping Attach the lift tube to the suction head with at least three layers of duct tape under each clamp...

Страница 10: ...unauthorized modifications Cutting the lift tube may change the characteristics of the VacuEasylift TAWI must authorize all modifications of the lift tube Use protective eye wear These instructions m...

Страница 11: ...capacity If the quick release attachment is used the touch bolt must be removed 10mm b The touch bolt provides help for the operator by opening the suction head valve fully enabling a good grip of th...

Страница 12: ...e unit with and without load to a con venient level for the operator This ensures that the control handle is within comfortable reach at all times 1 Press the main switch to turn the power on 2 Balanc...

Страница 13: ...13 Load adjustment knob positions with and without load standard handle Load adjustment knob positions with and without load flex handle...

Страница 14: ...st be executed before the vacuum lifter may be put into operation Motion limiters may not be used to limit the horisontal motion of the vacuum lifter The installa tion of a motion limiter may cause se...

Страница 15: ...ust be used only in a vertical position The max lifting capacity SWL must not be exceeded Use vacuum power only to handle the load Do not lift the load by hand force A load must never be left hanging...

Страница 16: ...a by pressing the operating handle right to the bottom and braking the seal c or b If a release valve is used option al accessory compatible with model VM0 40 50 180 270 and VM60 80 100 20 with flex h...

Страница 17: ...erify function of the lifter Note the colour code system for safe assembly of lift unit to suction foot accessory Each colour corresponds to a specific VacuEasylift model ONLY PARTS WITH MATCHING COLO...

Страница 18: ...essed air 5 The filter inset MUST be replaced when dirty or damaged 6 Reassemble the filter unit and mount it in the filter holder with the filter unit lid in the upward direc tion see figure 7 Verify...

Страница 19: ...rried out on a yearly basis If any damage wear is detected on the lifter this must immediately be reported to TAWI or au thorised TAWI representative The lifter must be taken out of commission and not...

Страница 20: ...and then stop the vacuum pump The load should be equivalent to the rated max lifting capacity and of a non porous material for example a steel plate A controlled sinking motion is correct anything els...

Страница 21: ...Check the direction of rotation of the vacuum pump Is air blowing from the silencer If not change the phas es over This must be carried out by a qualified electri cian see Install vacuum pump on page...

Страница 22: ...Check electrical parts and reset circuit breaker Main switch is turned off Turn main switch on PTC relay has tripped Let the vacuum pump cool down and verify that air flow is sufficient Reset the PTC...