22
3.3 Elektrische Installation
•
Connect the motor power connector X161 of the
control unit (1) with the motor power cable CU-
DU (4 pol) with the motor power connector
X361 of the drive unit (3).
•
Connect the data connector CU X162 of the
control unit (1) with the data cable CU-DU (17
pol.) with the data connector DU X362 of the
drive unit (3).
•
Connect the data connector CU X163 of the
control unit (1) with the Data cable CU-OP (7
pol.) with the data connector OP X363 of the
drive unit (3).
X361 X362
3
X261
2
X161
X162
X163
1
Fig.: 3.6
•
The thread tapping unit has a discharge current
more than 3,5mA.
To avoid electrical electromagnetic interference
and electric shock an installation of a second
earth wire is necessary (see chapter: „ Housing
grounding “)
•
Connect the grounding screw M6 of the cover
grounding X164 of the control unit (1) with an
earth wire with the earth connection
(min. 10 mm², cable length 2 m).
X164
1
A
Fig.: 3.7
•
Connect the power cable with the connector
X160 of the control unit (1).
•
Do
not
plug in the safety plug of the power
cable! (see chapter: „Installation“)
X160
1
Fig.: 3.8