UP050-EN Nozzle FN-1024 - Instruction and Maintenance Manual_rev2.docx
- 5 -
3-1. Daily inspection
1. Confirm that the nozzle & swivel do not leak with normal visual acuity.
2. Confirm that the nozzle & swivel have not deformation or other damages.
3. Inspect the splashguards, scarves, grip covers, and confirm that there are not damages and intense dirt.
Replace there as necessary.
3-2. Periodic inspection
(less than six months after installation)
1. Starts pump and confirm that the nozzle & swivel do not leak
.
2. Confirm the automatic shut off function of the nozzle (first and low latch position) according to “Testing
of 2.3”.
3. Confirm the pressure-controlled safety shut-off function of the nozzle according to “Testing of 2.3”.
4. Confirm that the electrical resistance between the nozzle tip and dispenser main ground terminal is less
than 1M
Ω
.
5. Confirm that the nozzle & swivel have not deformation or other damages.
6. Inspect the splashguards, scarves, grip covers, and confirm that there are not damages and intense dirt.
Carry out replacement if abnormality is discovered.
WARNING
1. Please read safety instructions "HINTS AND TIPS FOR SAFE USE" completely before inspecting.
2. Ground the approved metal test container and the nozzle surely.
Discharge the static electricity in the human body.
Static electricity may ignite gasoline vapours.
Splashguard
Scarf
Grip Cover
3. Maintenance