![Taski AERO 3500 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/taski/aero-3500/aero-3500_user-manual_820952006.webp)
6
Caution:
Ensure adequate ventilation when charging the bat
-
tery.
Notice:
The product safety data sheet provided by the bat
-
tery manufacturer must be observed.
Notice:
The operating instructions provided by the battery
manufacturer must be met.
Caution:
Always disconnect the batteries from the machine
before starting maintenance work.
Battery connection diagram
AERO 3500µicro (Gel)
6V batteries
12V batteries
Charging process
Caution:
Please pay careful attention to the instructions of
use provided by the manufacturer of the external
battery charging device.
Caution:
Each battery type and/or battery manufacturer re
-
quires different charging characteristics.
Incorrect charging characteristics or the use of inappro
-
priate chargers may result in early failure or the quick
destruction of batteries.
Notice:
Optionally available on-board chargers are adapted
to the battery size and contain several charging
curves, which are adjusted ex factory or by a TASKI
service technician for recommended batteries. This
regulation also applies for the use of stationary (ex
-
ternal) chargers.
Caution:
Persistent short-term use with subsequent battery
charging may cause long-term damage to the bat
-
teries.
- Standard value: At least approx. 20% of the available
capacity should be used up before recharging the bat
-
tery.
Caution:
In order to achieve the maximum possible service
life, traction batteries must run through a complete
charging cycle (12-16 hours) twice a week.
Caution:
Before decommissioning the machine for a longer
period, the batteries must run through a complete
charging cycle. The charger is then disconnected
from the machine and/or mains. Batteries gradually
discharge. Depending on the type of battery, they
must be recharged after 3-6 months.
- Before recommissioning, the batteries should run
through another complete charging cycle.
Charging procedure with external charger
Notice:
Only chargers recommended by the battery manu
-
facturer and certified according to SELV (safety ex
-
tra-low voltage) may be used.
Danger:
Do not plug the charger into the machine while it is
under tension (charger switched on).
The user may be injured by electric shock.
Warning:
Charging cables transfer high currents. Do not use
the charger if there are any signs of damage to the
plug, cable, or device connection.
Notice:
Make sure that the plug is inserted up to the stop in
order to ensure a good electrical contact.
Notice:
Check whether the plugged-in charger has started
the charging process.
6 V
6 V
6 V
6 V
125A
red
black
Power Board
Charger
Relay
12 V
125A
red
12 V
black
Power Board
Charger
Relay
• Connect the external battery charger with the battery
charging plug of the machine.