3.2 MECHANICAL SPECIFICATIONS

3.3 USE WITH SALT WATER

Use with salt water is permissible provided the equipment is thoroughly cleaned with fresh water after each use. The service life of the

equipment may be shortened due to the effects of corrosion, and is not covered under warranty. 

3.4 NOZZLE COUPLINGS

Master Foam nozzles in 250, 350, 500, 750, 1000, and 1250 gpm (950, 1325, 1900, 2900, and 4800 l/min) versions are available with a

2.5 inch coupling (NH, NPSH or BSP). 
Master Foam nozzles in 1500 and 2000 gpm (5700 and 7600 l/min) versions have a 3.5” (NH) coupling as standard. 
When tightening the coupling, make sure the foam inlet is pointing downward for ease of attaching the concentrate inlet hose.

3.5 ELECTRIC INSTALLATION

Nozzles with electric stream shaper actuation are shipped with a wiring diagram (TFT item #LIM-040). Other documentation is available

on request. ER nozzles are equipped with manual override in case of electrical power failure.

4.0  OPERATION

4.1 PATTERN CONTROL

The Master Foam’s spray pattern is adjustable from straight stream to a 90° wide fog. 
On models with manual shapers turning the stream shaper clockwise (as seen from the operating position behind the nozzle) moves the

shaper to the straight stream  position. Turning the shaper  counterclockwise  will  result  in  an  increasingly wider  pattern.  Only  90° of

rotation is required to go from wide fog to a straight stream. 
On RC Master Foam nozzles, use the FOG and STRAIGHT STREAM buttons on the operator station to change the pattern.
Since the stream trim point varies with flow, the stream should be “trimmed” after establishing a steady flow. To properly trim the stream,

first open to a narrow fog. Then close the stream to parallel to give maximum reach.

Range

SMALL

MEDIUM

LARGE

Nominal Flow

250 gpm

950 l/min

350 gpm

1325 l/min

500 gpm

1900 l/min

750 gpm

2900 l/min

1000 gpm

3800 l/min

1250 gpm

4800 l/min

1500 gpm

5700 l/min

2000 gpm

7600 l/min

Maximum Flow

306 gpm

1160 l/min

428 gpm

1620 l/min

612 gpm

2320 l/min

918 gpm

3475 l/min

1224 gpm

4630 l/min

1530 gpm

5790 l/min

1830 gpm

6930 l/min

2450 gpm

9270 l/min

Weight 

7.3 lbs / 3.3 kg

16.9 lbs / 7.7 kg

23.0 lbs / 10.4 kg

Nominal Operating Pressure

100 psi / 690 kPa / 7bar

Maximum Operating Pressure

150 psi / 1034 kPa / 10.3bar

Maximum Fog angle

90°

Operating Temperatures 

-40°F to 135°F

-40°C to 57°C

Materials used

Cast Aluminum, Aluminum 6000 series hard anodized MIL 8625 class 3 type 2, Stainless Steel 300 

series, Nylon, Nitrile Rubber

CAUTION

Mismatched or damaged waterway connections may cause equipment to leak or uncouple under 

pressure. Failure could result in injury. Equipment must be mated to matched connections. 

CAUTION

Dissimilar metals coupled together can cause galvanic corrosion that can result in the inability to 

uncouple the connection, or complete loss of engagement over time. Failure could cause injury. Per 

NFPA 1962, if dissimilar metals are left coupled together, an anti-corrosive lubricant should be 

applied to the connection and the coupling should be disconnected and inspected at least 

quarterly. 

WARNING

This device is not rated as ignition proof, explosion proof, or intrinsically safe. Use only in locations 

with adequate ventilation and no hazard of flammable vapor buildup. 

WARNING

The nozzle reaction is greatest when the shaper is in the straight stream position. Sudden changes 

in pattern can cause changes in reaction, leading to loss of footing or an out of control nozzle. The 

nozzle operator must be prepared for a change in reaction as the pattern is changed. 

NOTICE

Turning the shaper further forward will cause stream crossover and reduce the reach of the nozzle. 

NOTICE

The widest pattern is useful for protection and cooling, but does not educt foam. 

Содержание Master Foam Series

Страница 1: ...t shall have completed a course of education approved by the Authority Having Jurisdiction AHJ This instruction manual is intended to familiarize firefighters and maintenance personnel with the operat...

Страница 2: ...ment you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment...

Страница 3: ...vation Refer to LIM 030 and LIM 035 for effective stream trajectories of Task Force Tips Masterstream nozzles at 30 elevation This graph cannot be used to estimate maximum reach for elevation angles b...

Страница 4: ...OUPLINGS 3 5 ELECTRIC INSTALLATION 4 0 OPERATION 4 1 PATTERN CONTROL 4 2 FLUSHING DEBRIS 5 0 USE WITH FOAM 5 1 FOAM ASPIRATING ATTACHMENTS 5 2 CLEANING AFTER USE 5 3 SETTING FOAM PERCENTAGE 5 3 3 ORIF...

Страница 5: ...capable of supporting the nozzle reaction force FLOW REACTION FORCE gpm l min Pounds Kilograms 250 950 132 60 350 1325 185 84 500 1900 265 120 750 2900 397 180 1000 3800 529 240 1250 4800 661 301 1500...

Страница 6: ...ble 3 1 Figure 3 1A RANGE SMALL MEDIUM LARGE INLET COUPLING 2 5 65mm NH NPSH or BSP 3 5 89mm NH NPSH or BSP 3 5 89mm NH 4 0 100mm BSP RATED PRESSURE 100 psi 7bar 100 psi 7bar 100 psi 7bar FLOW RATING...

Страница 7: ...s LLC 2015 2020 7 LIZ 030 October 29 2020 Rev13 Figure 3 1B Figure 3 1C Stream Shaper Baffle Foam Inlet Coupling Serial Number Folding Handles Orifice Plate Override Knob Masterfoam 1000 1250 1500 200...

Страница 8: ...reach Range SMALL MEDIUM LARGE Nominal Flow 250 gpm 950 l min 350 gpm 1325 l min 500 gpm 1900 l min 750 gpm 2900 l min 1000 gpm 3800 l min 1250 gpm 4800 l min 1500 gpm 5700 l min 2000 gpm 7600 l min...

Страница 9: ...e air Generally the straight stream reach with foam is approximately 10 less than with water only Actual results will vary based on brand of foam hardness of water temperature etc For specific informa...

Страница 10: ...mply push it into the bore at the foam inlet on the nozzle The orifice plate has an O ring to hold it in place To remove the orifice plate hook a small object such as a screwdriver or Allen wrench int...

Страница 11: ...BRATION 0 5 and 1 Class A foam of 20 centipoise viscosity 3 3M ATC 3 AR AFFF product code ATC 603 6 3M ATC AFFF product code FC 600F PERCENT 1000 and 1250 gpm Nozzles FOAM USED FOR CALIBRATION 1 Willi...

Страница 12: ...20 40 60 80 100 120 140 160 180 200 220 A B A TFT MASTER FOAM B TFT MASTER FOAM WITH FOAMJET LX 3 or 1 FOAM AT 350 GPM AND 100 PSI Ver cal Distance Feet 0 10 20 30 40 50 60 70 Horizontal Distance Met...

Страница 13: ...0 140 160 180 200 220 240 260 280 300 0 10 20 30 40 50 60 Horizontal Distance Meter Ver cal Distance Meter Horizontal Distance Feet Ver cal Distance Feet 3 or 1 Foam at 1000 GPM 100 PSI 0 10 20 30 40...

Страница 14: ...ge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The orig...

Страница 15: ...mum of annually Units failing any part of this test must be removed from service repaired and retested upon completion of the repair 8 3 REPAIR Factory service is available with repair time seldom exc...

Страница 16: ...low is adequate as indicated by pump pressure and nozzle reaction BEFORE BEING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 There...

Отзывы: