7.1 PARTS LIST

ID QTY PART #

DESCRIPTION

1

1

SEE CHART

GASKET

2

1

SEE CHART

INLET COUPLING

3

1

SEE CHART

PLASTIC STRIP

4

6

VT31-18SH1.0 

5/16-18 X 1 SOCKET HEAD SCREW

5

1

A2120 

CONTROL VALVE FILTER

6

1

SEE CHART

VALVE BODY        

7

4

A2037 MOUNTING 

FOOT

8

1

VO-130 O-RING-130

9

1

VT25-28BH500  1/4-28 X 1/2 BUTTON HEAD SCREW

10

1

VW687X281-50  FLAT WASHER 1/4"

11

1

X382 DRAIN 

VALVE

12

1

X375 DRAIN 

HOUSING

13

3

A2135 

SPACER - .14ID X 1.00LONG

14

1

A2210 

SERVO - FUTABA

15

1

 A2132

GEAR 

16

3

VT06-32SH1.2 

6-32 X 1 1/4 SOCKET HEAD SCREW

17

1

VOM-1.9X2.8

O-RING METRIC 1.9 x 2.8

18

1

A2123

CONTROL VALVE SHAFT 

19

1

 A2131

GEAR

20

1

A2215 

SWITCH - PRESSURE 10 PSI

21

1

A2185

ELECTRONICS COMPARTMENT LID

22

4

VT25-20SH500

1/4-20 X 1/2 SOCKET HEAD SCREW

23

1

VR4250 

SNAP RING 1/2" EXTERNAL X .035

24

1

VO-014 O-RING-014

25

1

A2230

ANTENNA - 1/4 WAVE

26

1

VO-167 O-RING-167

27

1

A2141 

BATTERY COMPARTMENT LID

28

4

---

BATTERY - AA 1.5 VOLT LITHIUM

29

1

VO-154 O-RING-154

30

4

VT25-20BH375  1/4-20 X 3/8 BUTTON HEAD SCREW

ID QTY PART #

DESCRIPTION

31

2

A2136 TRANSDUCER 

RETAINER

32

1

A5845 

TRANSDUCER - PRESSURE

33

2

A2220 

SWITCH - REED

34

2

VO-013 O-RING-013

35

2

A2121 

CONTROL VALVE SEAT

36

1

A2122 

CONTROL VALVE BALL

37

1

VP188X.375

DOWEL PIN .188DIA X .375LONG

38

1

A2110 VALVE 

SHAFT

39

1

VO-220 O-RING-220

40

1

A2111 VALVE 

SLEEVE

41

1

A2126

RETURN SPRING

42

1

VO-236 O-RING-236

43

1

A2112 SLIDING 

PLUG

44

1

VO-214 O-RING-214

45

1

A2113 

VALVE SHAFT END

46

1

VO-243 O-RING-243

47

1

VO-211 O-RING-211

48

1

VT75-10LNT 

3/4" LOCK NUT

49

1

VT25-20SH500  1/4-20 X 1/2 SOCKET HEAD SCREW

50

1

VO-111 O-RING-111

51

1

A2114 VALVE 

SEAT

52

1

VO-252 O-RING-252

53

1

SEE CHART

OUTLET MATE

54

1

SEE CHART

CUP SEAL

55

1

SEE CHART

PLASTIC STRIP

56

1

SEE CHART

LOCKOUT SCREW

57

1

SEE CHART

OUTLET COUPLING

58

1

Y5946

LATCH SPRING

59

1

Y5945

HOLSTER

60

1

A2270

WIRELESS HANDHELD

7.2 INLET COMPONENTS

ID

QTY DESCRIPTION

4.0" STORZ

5.0" STORZ

6.0" STORZ

4.0" FEMALE

4.5" FEMALE

5.0" FEMALE

6

1

VALVE BODY        

A2101

A2101

A2101

A2101

A2100

A2100

1

1

GASKET

--

--

--

V3198

V3210

V3220

2

1

INLET COUPLING

A4124

A4125

A4126

A4562N

A4568NR

A4573NT

3

1

PLASTIC STRIP

A1292

A1291

A1291

A1291

A1293

A1293

 1

CUP 

SEAL

A1597

A1596

A1596

--

--

--

 1

LOCKOUT 

SCREW

A1294

A1294

A1294

--

--

--

 1

NFS 

RING

--

--

--

A4561

--

--

 1

O-RING

--

--

--

VO-248

--

--

 

1

MATE PSM4.25 X PSF5.25

A4730

--

--

--

--

--

1

CUP SEAL

A1596

--

--

--

--

--

1

PORT COVER

A1298

--

--

--

--

--

 1

PLASTIC 

STRIP

A1291

--

--

--

--

--

Содержание HYDRANT MASTER

Страница 1: ...his equipment Please call 800 348 2686 with any questions WARNING This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the Hydrant Master WARNING This manual should be kept available to all operating and maintenance personnel OPERATING RANGE Pressure Max 300 PSI Pressure Min 10 PSI TASK FORCE TI...

Страница 2: ...operable condition and has been maintained in accordance with the manufacturer s instructions 6 Failure to follow these guidelines may result in death burns or other severe injury FEMSA Fire and Emergency Manufacturers and Service Association P O Box 147 Lynnfield MA 01940 www FEMSA org Table Of Contents 1 0 MEANING OF SAFETY SIGNAL WORDS 2 0 SAFETY 3 0 GENERAL INFORMATION 3 1 VALVE SPECIFICATIONS...

Страница 3: ...for other purposes may involve hazards not addressed by this manual Seek appropriate guidance and training to reduce risk of injury WARNING Kinks in supply hose may reduce water flow and cause injury or death to persons dependant on water flow Avoid tight bends to minimize risk of hoseline kinks WARNING The Hydrant Master is not rated for use in explosive atmospheres WARNING The valve may be damag...

Страница 4: ...Specifications 900 MHz 2 4 GHz Transmitting Power 100mW 10mW Operating Range Line of sight 1200 ft 366m 600 ft 183m Operating Frequency 900 MHz 902 928 MHz 2 4GHz 2 410 2 470 GHz Agency Approvals 900 MHz 2 4 GHz FCC MCQ XBEEXSC OUR XBEEPRO Industry Canada IC 1846A XBEEXSC 4214A XBEEPRO Europe N A ETSI N A ETSI Finished Good AU RU 900 Contains FCC ID MCQ XBEEXSC The enclosed device complies with Pa...

Страница 5: ...5 3 6 FEATURE IDENTIFICATION AIR FLUSH PORT CONTROL VALVE SLIDING PLUG CONTROL VALVE BLEED DRAIN AUTOMATIC DRAIN VALVE CONTROL VALVE FILTER INLET OUTLET BATTERY COMPARTMENT VALVE INDICATOR AND MECHANICAL OVERRIDE ANTENNA DISPLAY AND CONTROL PANEL HANDHELD REMOTE CONTROL ...

Страница 6: ...pressure exceeds 5 psi 0 3 bar 3 7 4 LEDS LED COLOR STATUS MEANING Radio Link Green On Radio link present between valve and handheld remote control Radio Link Green Off Radio link not present Move handheld remote control closer to valve Low Battery Red Off Battery voltage is adequate to power valve or handheld Low Battery Red Blinking Battery voltage is low Replace Batteries See Section 6 1 Replac...

Страница 7: ...er is equipped with a flow controlling program to maintain a maximum flow of 1000 gpm for the first 15 seconds the valve is opening The valve position indicator will move to the full open position move back to the flow control position and then return to the full open position after 15 seconds The flow controlling program prevents a hose line from charging at a rapid rate and helps avoid water ham...

Страница 8: ...eel self tapping screws Make sure the area on the backside of the mounting surface is clear of obstructions A minimum thickness of 3 32 093 2 4mm in aluminum or 5 64 078 2mm in steel is recommended See the chart below to determine the correct pilot hole size Select proper location for mounting storage bracket Panel space required will be 6 0 x 11 2 152 x 285mm Refer to graphic below for dimensions...

Страница 9: ...remote control is unable to be taught it will exit teach mode by powering down after one minute On handheld remote control 1 Press and hold the Open and Closed buttons Press and release the Power button Continue to hold the Open and Closed buttons for 3 seconds Three decimal points on the display will turn on indicating the Handheld remote control is in Teach Mode Release the Open and Closed butto...

Страница 10: ...lve indicator is in closed position to ensure that valve is closed CAUTION Pressurizing hydrant with valve in open position could prematurely charge hose line Raise antenna on valve CAUTION Leaving antenna in the lowered position may reduce range of handheld remote control CAUTION Dissimilar metals coupled together can cause galvanic corrosion that can result in the inability to unscrew the thread...

Страница 11: ...ve VALVE FUNCTION Electronics opens control valve allowing water pressure to build in control chamber and open sliding plug POSITION FEEDBACK Flashing yellow green LEDs indicate sliding plug is moving to open position Constant green LED indicates sliding plug in fully open position OPERATOR INSTRUCTIONS When water is no longer desired push the Close button on handheld remote control or valve VALVE...

Страница 12: ...ar of obstructions The sliding plug moves freely Use Air Flush Port to test according to section 3 12 AIR FLUSH PORT Replace any missing or damaged parts before returning to service Any repaired device must be tested before being placed in service CAUTION Any alterations to the device and its markings could diminish safety and constitute a misuse this product 6 1 CHANGING BATTERIES HANDHELD CONTRO...

Страница 13: ...LD REMOTE CONTROL Handheld is flashing yellow LED Valve is off Power up valve 4 3 CONFIGURING HANDHELD REMOTE CONTROL Valve and handheld remote control are not linked properly Teach handheld Control valve opens but yellow and green LEDs continue to flash Valve is installed backwards Reinstall valve so flow arrow matches flow direction 5 1 PREPARING VALVE FOR USE Inadequate pressure Increase inlet ...

Страница 14: ... Copyright Task Force Tips Inc 2011 2012 LIA 520 April 25 2011 Rev01 14 7 0 EXPLODED VIEW 26 ...

Страница 15: ... A2136 TRANSDUCER RETAINER 32 1 A5845 TRANSDUCER PRESSURE 33 2 A2220 SWITCH REED 34 2 VO 013 O RING 013 35 2 A2121 CONTROL VALVE SEAT 36 1 A2122 CONTROL VALVE BALL 37 1 VP188X 375 DOWEL PIN 188DIA X 375LONG 38 1 A2110 VALVE SHAFT 39 1 VO 220 O RING 220 40 1 A2111 VALVE SLEEVE 41 1 A2126 RETURN SPRING 42 1 VO 236 O RING 236 43 1 A2112 SLIDING PLUG 44 1 VO 214 O RING 214 45 1 A2113 VALVE SHAFT END 4...

Страница 16: ...ty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and or property resulting from any defective equipment manufactured or assembled by TFT It is agreed and understood that the price stated fo...

Отзывы: