![Task Force Tips 350 Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/task-force-tips/350-series/350-series_manual_820853011.webp)
©Copyright Task Force Tips LLC 2010-2021
11
LIU-360 October 14, 2021 Rev05
11.0 TROUBLE SHOOTING
Table 11.0
12.0 EXPLODED VIEWS AND PARTS LISTS
Exploded views and parts lists are available at tft.com/serial-number.
SYMPTOM
POSSIBLE CAUSE
REMEDY
Eductor picks
up too much
foam
concentrate
Percentage Knob is set at higher percentage than desired
Turn knob to desired percentage
Eductor inlet pressure is incorrect
Set eductor inlet pressure to pressure specified on
labels
Metering head paired with incorrect body
Use correct metering head for body
Weak Foam or
No Foam
Out of foam or bucket is nearly empty
Refill tank
Percentage knob is set to lower percentage or is set to OFF Turn knob to desired percentage
Percentage ball is partially or completely plugged
Take off the meter head and clean debris out of the
percentage ball
Hose lay is incorrect
Correct hose lay per training approved by the AHJ
Eductor inlet pressure is incorrect
Set eductor inlet pressure to pressure specified on
labels
Hose is kinked
Straighten kinks out of hose
Concentrate intake hose is completely or partially clogged
Clean debris out of concentrate intake hose
Valve in nozzle is not fully open
Fully open valve in nozzle
Nozzle size is incorrect
Select correct nozzle
Nozzle is clogged
Flush nozzle to clear out debris or remove nozzle to
clean debris out
Foam has thickened due to cold temperatures
Use a foam suitable for temperatures