Tascam DA-3000 Скачать руководство пользователя страница 1

TASCAM DA-3000  

1

 

                    

DA-3000

 Release Notes

D01216500C

Updates

Always use the most recent firmware for this unit.
Please visit the TEAC Global Site (http://teac-global.com/) to 

check for the latest firmware.

New functions

V1.10 additions

•  A new function has been added that allows the search 

speed to be increased from 10x to 100x. When searching 

forward or backward (pressing and holding the 

.

 or 

/

 button), press and hold the other search (

.

 or 

/

) button to increase the search speed to 100x.

•  The peak hold indicator can now be set to display for a time 

of 1 to 10 seconds (in second increments).

•  When the current media has only 10 minutes of remaining 

recording time, the INFO indicator now lights red as a 

warning.

•  

PLAY MODE

 setting has been added to the 

PLAY 

FUNC

 page of the menu screen.

   Options

CONTINUE (default): All playable files in the currently 

selected folder will be played. 
SINGLE: Only the selected file will be played.

•  With the addition of the 

PLAY MODE

 setting, the repeat 

playback function has been changed. 

   Options

ON* 
OFF (default)
*A file or files will be played back repeatedly according 
to the 

PLAY MODE

 setting.

•  Mark information now appears in a pop-up whenever a 

mark is moved to or passed when searching.

Maintenance items

V1.11 fixes 

•  The Analog input and output signal levels could be 0.5dB 

different from the specified reference level. This has been 

fixed.

•  When the Input monitoring function is on (pressing the 

RECORD button with no media inserted into the currently 
selected device), changing settings on the 

REC FILE

 

page would result in the output becoming silent.  This has 
been fixed, this version now prevents settings on the 

REC 

FILE

 page from being changed in Input Monitor mode.

•  When pressing the MULTI JOG dial for setting confirmation, 

the wheel may turn slightly left or right, resulting in an 

unexpected menu item. The sensitivity to such unwanted 

movements has been improved.

V1.10 fixes 

•  When using an AES/EBU connection, if the output is Dual 

Wire mode, the INFO indicator now lights red in warning as 

it should. 

•  When the input signal monitoring function is on, operation 

will now immediately reflect the 

FILE

 and 

SAMPLE

 

settings on the 

REC FILE

 page as it should. 

NOTE

When the input signal monitoring function is off, these 

settings will not be reflected until the 

RECORD

 button is 

pushed. 

•  If a USB flash drive that was not formatted by a DA-3000 

is inserted into the unit, “Formatting not optimal. Format 

card? OK=ENTER” appeared in a pop-up message. This 

message has been changed to “Formatting not optimal.” 

NOTE

Please use media (USB flash drives, SD cards and CF cards) 

that have been formatted by this or another DA-3000 in this 

unit. 

•  A problem that prevented audio files larger than 64 MB 

from being copied between media has been fixed. 

•  When 

ADDA DIRECT

 mode is on, pressing the PLAY 

button causes this pop-up message to appear: “Cannot 

play while input monitoring.” Now, pressing the PAUSE or 

.

/

/

 buttons, trying to add a mark or move to a mark 

position will also cause this message to appear.

•  A problem that caused the reference level setting to 

change to –16 dB when the unit recovered from an external 

synchronization error has been fixed.

•  During playback of a DSDIFF or DSF file, direct location with 

a USB keyboard would not work (specifically, after 12:41 

when 5.6MHz and 25:21 when 2.8MHz). This has been fixed.

•  When using a cascade connection, the counters for values 

less than a second shown on the home screens on the 

synchronized units differed. This has been fixed.

•  When using a cascade connection, if the 

FILE TYPE

 

screen setting was changed from 

DSDIFF

 or 

DSF

 to 

WAV-24

 or 

WAV-16

, the slave unit would sometimes fail 

to receive commands from the master unit. This has been 

fixed. 

V1.01 fixes 

•  When a DSF file was in playback standby, moving forward 

to a mark position was not possible. This has been fixed.

•  If a file had a JPEG or another large tag frame*, the tag data 

could be broken. This has been fixed.

*Used for album cover information, for example 

•  File information on the 

INFORMATION

 screen would not 

be refreshed. This has been fixed.

•  When recording (or in recording standby) or monitoring 

with DSD, the meters would sometimes flicker. This has 

been fixed.

•  A problem with not being able to show LATIN-1 (ISO8859) 

characters has been fixed.

•  If there were character fonts not supported for display, the 

next character would be shown overlapping the previous 

character. This has been fixed.

•  Japanese handakuten would not be shown with half-width 

kana. This has been fixed. 

•  Button operation response using the RC-10 has been 

improved. 

•  If the Unlock item on the 

AUTO MARK

 screen was set to 

on, marks would be added even when not unlocked when 

recording DSD digital input. This has been fixed.