background image

U s e r   M a n u a l                                           M D T   8 0 0 0

21 

 

 

 

Suggested Settings for Stable Metal Detector Work

 

Suggested Settings for mineralized (black sand) salt water beach 

 

 

Set the threshold to -2. 

 

 

Set the Sensitivity 5. 

 

 

Black Sand (BlkS) ON. 

 

 

Salt Mode (St) ON.

 

 

Choose the desired Frequency.

 

 

Set the salinity level, if unknown to 28.

 

 

Ground Balance the Detector.

 

 

  

 

  

Suggested Settings for salt water beach 

 

 

Set the threshold to -2. 

 

 

Set the Sensitivity 7. 

 

 

Black Sand (BlkS) OFF. 

 

 

Salt Mode (St) ON.

 

 

Choose the desired Frequency.

 

 

Set the salinity level, if unknown to 28.

 

 

Ground Balance the Detector or preset the GB to 500.

 

 

 

 

 

 

 

 

 

 

 

Содержание MDT 8000

Страница 1: ...U s e r M a n u a l M D T 8 0 0 0 1 User Manual MDT 8000...

Страница 2: ...RE 14 6 TARGET ID AND SOUND MODES 15 6 1 NUMERICAL TARGET ID DISPLAY 15 6 2 SOUND MODES 15 6 2 1 Low Tone 15 6 2 2 Low High Tone 15 6 2 3 High low Tone 15 6 2 4 High Tone 15 6 3 ALL M ALL METAL 15 6 4...

Страница 3: ...U s e r M a n u a l M D T 8 0 0 0 3 Assembly...

Страница 4: ...U s e r M a n u a l M D T 8 0 0 0 4 1 Insert the two rubber washers into the holes on either side of the lower shaft 2 Slide the lower shaft into the search coil mounting bracket 1 2...

Страница 5: ...U s e r M a n u a l M D T 8 0 0 0 5 3 Insert the search coil mounting bolt through the search coil mounting bracket 4 Fasten the search coil mounting nut Do not overtighten the nut 3 4...

Страница 6: ...U s e r M a n u a l M D T 8 0 0 0 6 5 Loosen the middle shaft clamp 6 Insert the lower shaft into the middle shaft Lock the clamp 5 6...

Страница 7: ...M D T 8 0 0 0 7 7 Loosen the upper shaft clamp 8 Insert the middle shaft into the upper shaft Lock the clamp 9 Connect the coil cable connector to the control housing coil connector and tighten the r...

Страница 8: ...for more than 3 seconds to activate or deactivate the Tracking Minus Arrow Button Decrement the setting icon highlighted by the cursor Press and release the button to decrement the setting by 1 Press...

Страница 9: ...ht Deactivated Target ID Range 30 to 30 OR Signal Strength when in PP mode Rage 0 99 Gb Ground Balance Range 0 to 999 When the cursor highlights the Gb icon the Ground Balance can be adjusted by using...

Страница 10: ...tivate Salt Mode and adjust the salinity level 1 Press and release the TS button until the cursor highlight s the St Salt icon Press and release the Mode button to activate salt mode St in black and a...

Страница 11: ...nu button until the cursor highlights the Trh icon 2 While the cursor highlights the TrH icon adjust the Threshold level with Plus Arrow or Minus Arrow buttons Disc To adjust the discrimination set po...

Страница 12: ...r highlights the Gb icon 2 While the cursor highlights the Gb icon adjust the Ground Balance with Plus Arrow or Minus Arrow buttons Sound Modes Press and release the Mode button to toggle between the...

Страница 13: ...activated and idling for more than 8 seconds the cursor will automatically highlight Volume a For quick Volume adjustment press and release PP 2 While the cursor highlights Vol icon adjust the Volume...

Страница 14: ...rical signal strength indicator with range from 0 99 and amplitude and frequency modulated sound associated with the target signal strength Pin Point 1 Lower the search coil approximately 1 above the...

Страница 15: ...vity non ferrous Targets Only heard in Discrimination and Mix Mode 1 All M All metal Only the Low High tone will be heard when a Target is located Numerical Target ID is always present in All Metal Mo...

Страница 16: ...int is set at a value greater than 0 any Target ID lower than 0 will be silenced any Target ID within 2 of the Discrimination Set Point will be silenced The dashed lines indicate the silenced regions...

Страница 17: ...irable false signals Procedure 1 Activate the Manual Ground Balance function 2 Move the search coil up and down starting from 1 inch above the ground level up to approximately 4 to 5 inches while keep...

Страница 18: ...old the ground balance button While holding the ground balance button raise the coil 4 5 inches above the ground while keeping the coil parallel to the ground and release the ground balance button 3 T...

Страница 19: ...INK HOLES ETC WHEN DOING STEP 4 YOUR SAFETY SHOULD ALWAYS COME FIRST 5 Move the search coil up and down starting from 1 inch above the water level up to approximately 6 to 8 inches while keeping the s...

Страница 20: ...ing a negative threshold the value is subtracted from the target signal A Threshold of zero does not affect the signal To increase the ability to hear faint signals it is recommended to set the TrH to...

Страница 21: ...sitivity 5 Black Sand BlkS ON Salt Mode St ON Choose the desired Frequency Set the salinity level if unknown to 28 Ground Balance the Detector Suggested Settings for salt water beach Set the threshold...

Страница 22: ...otch filter Audio Modes All Metal Discrimination Mix Audio Output Speaker Headphones Display 128X64 Graphic LCD LCD Backlight Yes Battery 26650 Rechargeable Lithium ion battery 3 7V 5000mAh Battery Li...

Отзывы: