DRAFT
7
4.0
Test procedure of the electrical system
Bring the machine to a stable position in a clear area. Any person not involved in the test should
leave the area nearby the machine.
Check before test:
Step 1.
1.
Connect the power supply to the input plug (15) and the yellow lamp (3) will turn on to
indicate correct supply of electricity. Be sure to use a safety cable with undamaged plugs.
2.
Check that the emergency stop (2) is pulled over to the operating position.
3.
Turn the reversing switch (1) to position 1 that indicates that you have chosen an
unknown running direction for the motor. (Wrong direction are not important for this
test)
4.
Push the start button (4) and the main motor start to run in the first step start position.
Wait for 6 -8 seconds and the system turn automatically over to the second and final
start position. The green lamp (6) will now turn on indicating that the motor is working
correct. Look and listen to ensure that everything works perfectly.
5.
Stop the machine by pushing the stop button (5).
Step 2.
6.
When the machine has come to a complete stop, turn the reversing switch (1) to position
2 and repeat the start procedure described in item 4 above. The motor running direction
shall now be opposite of test 1.
7.
When the machine runs smoothly, push down the emergency stop (2). All electricity hall
be cut off and the motor will stop.
Final step. Correct motor running direction (16) is very
important for all further operation of the
If you have problems with this test, please call for professional assistance. Do not try
to open the electric system. Touching the components inside the electric system is
hazardous!
That no blade is mounted
On the blade shaft.
That all covers and guards
are mounted on the
machine.
That the movable frame is
lowered to the ground.
Содержание FS 1218 EX
Страница 2: ...DRAFT 2 ...