10. TECHNICAL SPECIFICATIONS
Type...........................................
ECO II FEEDING
Mains supply fuse F1 ...................
1A, fast-blow
Module power fuse F2 .................
1A, fast-blow
Mains supply/frequency................ 115/230V+10% -20%, 20VA, 50/60Hz
Housing ...................................... IP54, plastic casing
Operating temperature ................. 0 to 40°C
Storage temperature .................... -15 to 50°C
Ambient relative humidity ............ max. 95%
Pollution degree .......................... 2
Altitude ...................................... Up to 2000m
Installation Category: ................... Class II
Type...........................................
PSM-8
Mains supply fuse F1 ...................
1A, fast-blow
Mains supply/frequency................ 115/230V+10% -20%, 12VA, 50/60Hz
Housing ...................................... IP54, plastic casing
Operating temperature ................. 0 to 40°C
Storage temperature .................... -15 to 50°C
Ambient relative humidity ............ max. 95%
Sensor supply ............................. 12VDC, 200mA total max.
Type...........................................
CDM-1
Mains supply fuse F1 ...................
1A, fast-blow
Mains supply/frequency................ 230V+10% -20%, 2HP, 50/60Hz
Housing ...................................... IP54, plastic casing
Operating temperature ................. 0 to 40°C
Storage temperature .................... -15 to 50°C
Ambient relative humidity ............ max. 95%
Chain disk motor ......................... 230Vac / 2HP max
Nema Code Letter:.................... A to L
Full-load amps (FLA): ................ 13A max
Locked rotor amps (LRA): .......... 170A max
!
Running a motor with higher ratings could result in potential
controller damages and/or fire. If the Nema Code Letter is not
available, exclusively use the LRA ratings!
The room temperature where the controller is located must always
remain between 32
o
and 104
o
F (0
o
and 40
o
C).
For indoor use only.
15
ECO II FEEDING rev.06
ECO II FEEDING
• Option 7
(continuous feeding with no blend curve and no feed blend)
Principle of Operation:
Each time a drop is empty, the controller fills it up with a specific ingredient.
Refer to section 2.4.3 to get information about the drops’ filling process when
using the continuous feed distribution method.
Settings:
Disable the blend curve (section 5.3).
Disable feed blends (section 5.3).
Select the ingredient used by each drop (section 6.3).
Enable the Continuous Feeding option (section 5.3).
• Option 8
(continuous feeding without blend curves and with feed blends)
Principle of Operation:
Each time a drop is empty, the controller fills it up with a specific feed blend.
Refer to section 2.4.3 to get information about the drops’ filling process when
using the continuous feed distribution method.
Settings:
Disable the blend curve (section 5.3).
Enable feed blends (section 5.3).
Select blend ingredients (section 6.1.1)
Select the feed blend used by each drop (section 6.3).
Enable the Continuous Feeding option (section 5.3).