12
ECO II FEEDING rev.06
ECO II FEEDING
• Option 2
(continuous feeding with blend curves and feed blends)
Principle of Operation:
Each time a drop is empty, the controller fills it up with a feed blend that
suits the animal age of the drop.
Refer to section 2.4.3 to get information about the drops’ filling process when
using the continuous feed distribution method.
Settings:
Enable the blend curve (section 5.3).
Enable feed blends (section 5.3).
Blend curve settings:
Select the ingredient according to the animal age (section 6.1.2.1).
Select the blend curve used by each drop (section 6.3).
Enable the Continuous Feeding option (section 5.3).
• Option 3
(variable feed cycles with blend curves and without feed blends)
Principle of Operation:
The controller delivers feed according to the settings of each drop's blend
curve: when the feed cycle of a blend curve is active, the controller sends the
ingredient and dosage that suit the drop's animal age. The activation of feed
cycles is also based on the animal age.
Refer to section 2.4.3 to get information about the drops’ filling process when
using feed cycles.
Settings:
Enable the blend curve (section 5.3).
Disable feed blends (section 5.3).
Blend curve settings:
Select the ingredient and dosage according to the animal age (section 6.1.2.1).
Select the blend curve used by each drop (section 6.3).
Disable the Continuous Feeding option (section 5.3).
Set the start time of each feed cycle (section 6.2).
Enable the “Active Feed Cycles in Curve” option (section 5.3).
Select active feed cycles according to the animal age (section 6.1.2.2).
65
ECO II FEEDING rev.06
ECO II FEEDING
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
OUTPUTS
1
2
3
4
5
6 7
8
9 10 11 12 13 14 15 16
4 5
6
7
8
9 10 11 12 13 14 15 16 17 18 19
OUTPUTS
Bin 1
Bin 1
Bin 2
Bin 2
Bin 3
Bin 3
Bin 4
Bin 4
Feed Scale
Feed Scale
Flexible auger 1
Flexible auger 1
Flexible auger 2
Flexible auger 2
Clock 1
Clock 1
Clock 2
Clock 2
Clock 3
Clock 3
Clock 4
Clock 4
Clock 5
Clock 5
Clock 6
Clock 6
Clock 7
Clock 7
Clock 8
Clock 8
Drop 1
Drop 1
Drop 2
Drop 2
Drop 3
Drop 3
Drop 4
Drop 4
Drop 5
Drop 5
Drop 6
Drop 6
Drop 7
Drop 7
Drop 8
Drop 8
Drop 9
Drop 9
Drop 10
Drop 10
Drop 11
Drop 11
Drop 12
Drop 12
Drop 13
Drop 13
Drop 14
Drop 14
Drop 15
Drop 15
Drop 16
Drop 16
Drop 17
Drop 17
Drop 18
Drop 18
Drop 19
Drop 19
Drop 20
Drop 20
Drop 21
Drop 21
Drop 22
Drop 22
Drop 23
Drop 23
Drop 24
Drop 24
Drop 25
Drop 25
Drop 26
Drop 26
Drop 27
Drop 27
Drop 28
Drop 28
Drop 29
Drop 29
Drop 30
Drop 30
Drop 31
Drop 31
Drop 32
Drop 32
Drop 33
Drop 33
Drop 34
Drop 34
Drop 35
Drop 35
Drop 36
Drop 36
Drop 37
Drop 37
Drop 38
Drop 38
Drop 39
Drop 39
Drop 40
Drop 40
Drop 41
Drop 41
Drop 42
Drop 42
Drop 43
Drop 43
Drop 44
Drop 44
Drop 45
Drop 45
Relay 1-16 &
Relay 17-32 = second 16-relay strip of 32 outputs
relay panel
Relay Panel's identification number
(ID # 4 to ID #19)
12.1 Relay Assignment