Страница 1: ...Tarana Wireless Inc Proprietary 2021 All rights reserved BN Installation Guide vIG_BN_2022 07 0 Base Node Installation Guide vIG_BN_2022 07 PN 18 0007 001 Rev 1 0...

Страница 2: ...OLE MOUNT BRACKET ASSEMBLY 19 MOUNTING THE BRACKET EARS 20 MOUNTING THE BNTO THE BRACKET 20 ANTENNA AIMING 23 ADJUSTING THE AZIMUTH 23 ADJUSTING THE TILT 24 POWER AND CONNECTIVITY 25 PHYSICAL CONNECTI...

Страница 3: ...LIER S DECLARATION OF CONFORMITY CBRS 43 REGULATORY INFORMATION 44 DEPLOYMENT IN THE US FCCSTATEMENT 44 DEPLOYMENT IN CANADA INDUSTRY CANADA STATEMENTS 44 RESOLUTION 680 BRAZIL 46 USACBRSBAND CATEGORY...

Страница 4: ...ice voids the warranty Do not stack anything on the radome Dust covers must be installed on all connectors when not in use Cable ends must be protected from weather if not connected to the device When...

Страница 5: ...ted equipment Safety Signs Surface temperature and heavy equipment warning signs are required on this equipment Surface Temperatures The external equipment surfaces become warm during operation due to...

Страница 6: ...NING Making adjustments and or modifications to this equipment that are not in accordance with the provisions of this Installation Guide User Guide or other supplementary documentation may result in p...

Страница 7: ...bend them beyond their minimum bending radius Protect cover unconnected optical fiber connectors with dust caps Grounding Connections Reliable grounding of the BN chassis must be maintained Mains Powe...

Страница 8: ...Tarana Wireless Inc Proprietary 2021 All rights reserved BN Installation Guide vIG_BN_2022 07 7...

Страница 9: ...ping tool 6 AWG Customer Supplied Equipment Power cable a 2 wire outdoor rated cable of suitable size for the cable run or as per local code Ethernet cable shielded CAT5e CAT6 Grounding wire 6 AWG PC...

Страница 10: ...the BN is larger than 10AWG A DC Defender DC Surge Protector w Mounting Kit 1101 1110 KT B DC Defender DC Surge Protector 1101 1027 2 Pole Mount Kit 1000 1702 See Appendix A for instructions on insta...

Страница 11: ...site or 48VDC from the Tarana AC DC outdoor rated power adaptor using AC power from the site Regardless the DC power cable must be terminated with a Harting Push Pull quick disconnect IP67 rated conne...

Страница 12: ...in this port will make removing the cable difficult and could damage the port Harting Ethernet cable assemblies for this purpose are available through Tarana Upon receiving power the BN will undergo t...

Страница 13: ...n at the BN on the tower This SFP module is MEF certified with an extended temperature range of 40 to 85 C DATA3 is a copper interface and only supports 1Gbps Devices connected to DATA3 must be Gigabi...

Страница 14: ...of band management interfaces Configuration Note The following is for the 5GHz BN For CBRS BN configuration see Appendix C CBRS Installations From the BN s web UI the following information needs to b...

Страница 15: ...240 0 0 12 2 The Data VLAN required and the Management VLAN optional must be separate VLANs 3 The IP subnet associated to the Data VLAN ingressing to the BN s data port must be different from the In b...

Страница 16: ...reserved BN Installation Guide vIG_BN_2022 07 15 Unmute Radios 1 Click Radio Control Up Note For safety the radios are muted by default After verifying functionality mute the radios again until after...

Страница 17: ...e of those ports must be connected to the Internet for the BN to contact the TCS Remember that Data Ports 1 and 2 are 10 Gbps only Data Port 3 is 1 Gbps only Login to Tarana Cloud Suite TCS using the...

Страница 18: ...oes appear in the Devices List page it may not have been assigned to a Sector in TCS Under Admin Network Configuration check if this BN is in the BN Devices Unassigned folder The BN must be assigned t...

Страница 19: ...zero degrees and the azimuth to the required direction Note The hardware supplied for pole mounting and adjustment have a pre applied anti seize dry film coating There is no need to apply anti seize l...

Страница 20: ...bolts for poles 60 3 mm 101 6 mm 2 3 8 3 Use 4 M8 1 25 x 120 mm bolts for poles 101 6 mm 127 mm 3 5 o Measure Pole Diameter 95mm in this example Figure 4 Measure Pole Diameter Install the BN bracket o...

Страница 21: ...for all bolts at approximately 70 10 N m 7 4 lb ft Repeat the torque sequence for all bolts until each bolt is stabilized at 15 N m 11 lb ft Figure 5 Torque Sequence Mounting the Bracket Ears When ins...

Страница 22: ...N must be slid into the top slots on the bracket ears using these two bolts Slide the BN into the top slots in the bracket ears using the partially installed bolts from Step 1 Ensure that the wedge lo...

Страница 23: ...ts with incremental steps at approximately 40 70 and 100 of full torque rating Following the torque sequence shown torque all bolts to values of approximately 40 6 N m 4 4 lb ft Continue with the same...

Страница 24: ...use the mount to lose tilt adjustment after some temperature cycles or vibration In turn this will cause a tower climb and or service disruptions Adjusting the Azimuth Adjust the azimuth by loosening...

Страница 25: ...a digital level with 0 2 deg accuracy Torque the 3 M8 x 180mm in a gradual triangular pattern NOTE The total adjustable tilt is 20 degrees Torque the bolts in a clockwise pattern Torque all bolts to...

Страница 26: ...nector There are three options for a data connection two SFP ports DATA 1 DATA 2 and one Gbps Ethernet port DATA 3 For in band management the default IP address for these ports is 192 168 11 2 The def...

Страница 27: ...s document NOTE For on site OOB management follow these additional steps Pre assemble the Harting RJ45 pigtail upper lightning arrestor grounding wire shielded CAT5e CAT6 lower lightning arrestor for...

Страница 28: ...booting and initializing process for a period of 5 7 minutes There are a set of LEDs on the bottom edge of the BN that will cycle through patterns and colors during this time At the end of this period...

Страница 29: ...ough the web UI If DHCP is used for the in band management IP address a static address must be used for the out of band management address if used It is optional to assign in band management traffic t...

Страница 30: ...e URL cloud taranawireless com For username and password contact the TCS system administrator From the left column click on DEVICES Verify that BN is selected from the RN BN switch Verify the BN is on...

Страница 31: ...stallation Guide vIG_BN_2022 07 30 Diagnostics From TCS login to the BN s Web UI Note This will require OP Admin rights Log in to the BN Web UI Check the Diagnostics page This is an important step and...

Страница 32: ...node side of the DC Defender installation PN 33 0004 XXX where XXX length in meters 1 DC cable for the power source side of the DC Defender installation not included o Belden 15240F1 or equivalent 16...

Страница 33: ...gure 9 Completed DC Cable Assembly DC Defender 48 5Assembly The complete DC Defender assembly with cover removed is shown below Note The left two terminal lugs should be connected to the DC power sour...

Страница 34: ...und wire not provided to the DC defender using the provided ground screw star washer The ground wire should be as short as possible less than 3 feet between the DC Defender and the site grounding poin...

Страница 35: ...on PN 33 0004 XXX where XXX length in meters 1 DC cable for the power source side of the DC Defender installation not included o 9 AWG or larger stranded 7x24 tinned copper conductors PVC insulation B...

Страница 36: ...node and the other connecting to the DC power source Strip the DC cable insulation to 1 4 The drain red and black wires will be exposed Cut the red wire to 1 from the cable jacket Strip the insulatio...

Страница 37: ...suppressor Thread the power cable from the power source to the strain relief adjacent to the power connector marked input Strip the cable jacket as needed Strip the power conductors 0 4 10mm and conne...

Страница 38: ...se to the Tarana Base Node as possible using the provided hardware and the concealed mounting holes Mount the unit in the orientation shown with the UP marking on the lid facing upward and the cable s...

Страница 39: ...d taranawireless com 443 to registration trial cloud taranawireless com 443 Click on Installation Parameters Verify the latitude longitude and tilt received from GPS unit on the BN and the height and...

Страница 40: ...roprietary 2021 All rights reserved BN Installation Guide vIG_BN_2022 07 39 After entering the BN installation parameters verify that the BN is broadcasting which is indicated by the Radio Control ico...

Страница 41: ...the CPI ID number in the CPI ID field and not the CPI Certificate number For example note the similarities between a Google p12 file name and the related CPI ID GOOG 000365_2295819 name of p12 file G...

Страница 42: ...button in the green device summary card Here you can verify that the BN has been assigned spectrum In the example on this page the dark green indicates that the spectrum has been granted and authoriz...

Страница 43: ...Tarana Wireless Inc Proprietary 2021 All rights reserved BN Installation Guide vIG_BN_2022 07 42 Supplier s Declaration of Conformity 5GHz...

Страница 44: ...Tarana Wireless Inc Proprietary 2021 All rights reserved BN Installation Guide vIG_BN_2022 07 43 Supplier s Declaration of Conformity CBRS...

Страница 45: ...provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not i...

Страница 46: ...oit tre install par un professionnel Tarana Wireless Inc n approuve aucune modification apport e l appareil par l utilisateur quelle qu en soit la nature Tout changement ou modification peuvent annule...

Страница 47: ...il Regulamento Anatel sobre equipamentos de Radiocomunica o de Radia o Restrita Resolu o n 680 Este equipamento n o tem direito prote o contra interfer ncia prejudicial e n o pode causar interfer ncia...

Страница 48: ...r a CBSD or Domain Proxy communicates with a SAS TLS v1 2 shall be used to perform authentication Previous versions of TLS e g TLS v1 1 per RFC 4346 TLS v1 0 per RFC 2246 or SSL v3 0 shall not be used...

Страница 49: ...nRequest object to the SAS with parameters that identify the CBSD to the SAS provide specific information on the CBSD equipment capabilities and identifies the measurement reporting capabilities of th...

Страница 50: ...CLAIMER Except as specified above all express or implied conditions representations and warranties including without limitation any implied warranty or condition of merchantability fitness for a parti...

Отзывы: