- With the ignition off, hold the Reset button until the LED flashes 2 times (5 seconds).
Block Function:
- Activates when opening and closing the door with the ignition on and not pressing the
RESET button.
To cancel the valet function, turn on the ignition and press the Reset button for 1 second,
The LED will flash 1x (once) confirming cancellation.
- After 50 seconds, the LED flashes and the siren goes off if installed (not included),
another 20 seconds the progressive block initiates. Definitive blockage occurs after
another 30 seconds.
- To CANCEL the LOCKOUT, press the RESET button at any time, the LED will flash 1(once)
to indicate the lockout cancellation..
Operation
VALET Function:
- Temporarily cancels the Lock function. It is used when leaving the vehicle in a parking
lot, without the need to indicate the location of the Reset button (secret) to the valet.
Installation Scheme
4 - Green - Ground Signal Door Switch
5 - Black/Yellow - Alarm Siren Output
6- Red +12V
9 - Black- GND
3 - White/Black- LED +
2 - White/Black - Reset Button
8 - Black- LED GND
7 - Black- GND
10 - Blue - POST IGNITION
RESET
BUTTON
BLOCK
MAX 20A
1 - Green/White - Positive Signal Door Switch
LED
Содержание Tarsafe G2