3. MAINTENANCE
IOM manual - Sanitary series
25
3.7.
T80-T425
–
Disassembly of the pump
The numbers put in brackets, refer to the part numbers in the spare part drawings and spare
part lists in chapter
5
.
3.7.1.
Before the disassembly procedure
Be sure to drain all liquid from the pump. Cleanse or neutralize the pump thoroughly.
Disconnect the air supply and then the suction and discharge connections. Due to size and weight,
two persons are required to conduct service.
3.7.2.
Disassembly procedure
Fig. 3.7.1
Unscrew and remove two tri-clamps [138]
connecting the manifold [132] to the housings [11].
Fig. 3.7.2a
Take off the manifold [132].